STACK PORT PROVIDED AND INSTALLED BY CUSTOMER
GAS FLOW
4"
ANSI #150
FLANGE PROVIDED
AND INSTALLED BY CUSTOMER
STACK WALL
IMPORTANT FOR ASSEMBLY:
THERMOCOUPLE IS TO BE INSTALLED BEFORE
PITOT TUBE TO AVOID INTERFERENCE
INSTALL HIGH TEMP
GASKET
TML P/N 99702004
ADJUST PITOT TUBE TO DESIRED DEPTH BEFORE
SECURING IN PLACE BY TIGHTENING
COMPRESSION FITTING
PRESSURE UNIONS TO BE ORIENTED
VERTICALLY, PARALLEL WITH
STACK FLOW
UMBILICAL SECTION
(TO BE INTERFACED
WITH PITOT)
3:1 HEATSHRINK BOOT
(UNSHRUNK)
SAMPLE LINES
(3/8" O.D.)
THERMOCOUPLE WIRE
TEFLON TUBING PROTECTING
THERMOCOUPLE WIRE
(PROVIDED IN HARDWARE KIT)
TERMINATE INTO THERMOCOUPLE
HEAD
SEAL THERMOCOUPLE
TEFLON TUBE INTO GLAND
PITOT LINES MUST RUN
VERTICAL AT LEAST 1 FOOT -
PREVENTING CONDENSATE
FROM DRIPPING DOWN TUBES
RESERVE 4 FEET OF UMBILICAL
MINIMUM FOR SERVICE LOOP
1.5ft MINIMUM FROM BOOT TO FITTING
3ft MINIMUM FROM BOOT TO GLAND
HEATSHRINK BOOT DETAIL
NOTE:
TEFLON TUBING TO BE INSERTED INTO BOOT PRIOR TO
APPPLYING HEAT. OBTAINING A PROPER SEAL ON THE
THERMOCOUPLE WIRE IS CRITICAL.
REVISIONS
DATE
APPROVED
BY
REV.
DESCRIPTION
8AUG2017
X1
PRELIMINARY INSTALLATION DRAWING & DETAIL
22JAN2018
A
RELEASED PER ECO7228
A
A
B
B
C
C
D
D
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
THIS DOCUMENT CONTAINS
INFORMATION PROPRIETARY
AND CONFIDENTIAL TO
TELEDYNE MONITOR LABS,
INC. AND IS FURNISHED UPON
THE EXPRESS CONDITION
HEREIN WILL NOT BE
DUPLICATED, REPRODUCED,
DISCLOSED OR DISSEMINATED
TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN IN
CONNECTION WITH THE
EVALUATION THEREOF
WITHOUT THE PRIOR WRITTEN
CONSENT OF TELEDYNE
MONITOR LABS, INC.
--
DO NOT SCALE
DRAWING
PART NO.
A
SHEET 1 OF 1
DRAWN BY
99702100
SCALE: 1:5
REV
MATERIAL
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES:
0.X 0.1 0.XX 0.02 0.XXX 0.010
ANGULAR: MACH 0 30'
BEND
D
DWG. NO.
DF180 PROBE INSTALLATION
FINISH
DATE
TITLE:
SIZE
D.CONNELLY
2NOV2017
N/A
N/A
TRANSFER OF EAR99 TECHNICAL INFORMATION
USE AND DISCLOSURE OF DATA:
INFORMATION CONTAINED HEREIN IS CLASSIFIED AS EAR99 UNDER
THE U.S. EXPORT ADMINISTRATION REGULATIONS. EXPORT,
REEXPORT OR DIVERSION CONTRARY TO U.S. LAW IS PROHIBITED.
Summary of Contents for Deltaflow DF180
Page 36: ...January 2018 Page 36 Appendix B Drawings ...
Page 37: ......
Page 40: ......
Page 41: ......
Page 42: ......