4 – Electrical Installation
4-4
© Teledyne TSS
DPN 402196 Issue 4.1
distribution system. All cores in the cable are 1.25mm² cross-section. See
"Communication Link SEP to SDC" on page 4-8
and the cable drawing number B930473 in
for further details.
Lay the Power and Communications cable from the ROV electrical distribution system to the PSU.
Route the cable along fixed ROV frame members and use cable clips to secure it at regular intervals.
Avoid applying any sharp bends or other points of mechanical stress along the cable.
Connect the Power and Communications cable to the 8-way male ‘Power/Comms’ port on the PSU.
Tighten the knurled locking collar by hand only.
Do not overtighten this connector.
Before you assemble any electrical coupling in the sub-sea installation, inspect the pins and
receptacles of all connectors for signs of damage, contamination or corrosion. Follow the instructions
in
section 4.1.2 "Care of Sub-sea Connectors" on page 4-3
to clean and care for the connectors.
CAUTION
It is very important to provide a good ground connection on pin number 2 of the
cable. A poor or a missing connection will severely degrade the performance of
the 440 System. You must make all connections to the ROV using waterproof
connectors or splices of good quality.
4.1.3.1 Power Requirement
The standard PSU operates from an AC electrical supply in the range 100 to 120V AC, 45 to 65Hz. The
System draws approximately 2.8A at 110V nominal supply voltage. The same PSU can operate from a
DC supply in the range 140 to 170V with no further adjustments necessary.
See
and make the correct power connections from the ROV electrical distribution system to
your PSU.
Table 4-2: Power and Communications cable
Connector Pin Number
(and Wire number)
Function
Core colours
1 (N)
Supply neutral line/L2
Blue
2 (E)
ROV ground (refer to sub-section 4.1.1 "Ground Connections”
beginning on page 4-3)
Dark Green
3 (L)
Supply 110V live/L1 (or +140 to +170V DC)
Brown
Pin 4 (wire number 1)
Comms 1
Orange
Pin 5 (wire number 2)
Comms 2
White
Pin 6 (wire number 3)
Comms 3
Red
Pin 7 (wire number 4)
Comms 4
Yellow
8 (no connection)
Linked internally to the cable screen
Screen
Summary of Contents for 440
Page 12: ...List of Figures x Teledyne TSS DPN 402196 Issue 4 1 ...
Page 18: ...Glossary xvi Teledyne TSS DPN 402196 Issue 4 1 ...
Page 24: ...1 Introduction 1 6 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 32: ...2 System Overview 2 8 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 66: ...4 Electrical Installation 4 20 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 88: ...5 Operating Software 5 22 Teledyne TSS DPN 402196 Issue 4 1 Figure 5 10 Altimeter Test ...
Page 144: ...6 Operating Procedure 6 40 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 154: ...7 Operational Considerations 7 10 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 164: ...8 System Specifications 8 10 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 203: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 17 Figure 10 15 SDC10 Dimensions ...
Page 230: ...A Operating Theory A 12 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 242: ...B Options B 12 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 244: ...C Altimeter C 2 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 246: ...D Reference D 2 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 248: ...D Reference D 4 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 250: ...D Reference D 6 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 252: ...D Reference D 8 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 254: ...D Reference D 10 Teledyne TSS DPN 402196 Issue 4 1 ...