Errors and Faults
In the event that the OLCT 80 detects a fault or error:
•
The orange
indicator light (Figure 4, 2) will illuminate.
•
A specific message will be displayed (Figure 4, 5).
Cause of the error or fault
Display
Corrective action
Zero fault
Follow the zeroing procedure (see page 68).
Sensitivity fault
Adjust sensitivity; see page 68.
Worn sensor
Replace the sensor; see page 76.
Main sensor missing
The main sensor is disconnected. After taking all of
the necessary safety precautions (if the
OLCT 80
is
installed in an ATEX zone), open the cover of the
OLCT 80
and check the connection between the
sensor and the terminal on the printed circuit board.
Reading out of range
The gas concentration measured is outside the
sensor's approved measurement range.
Negative reading
Follow the zeroing procedure (see page 68) or
replace the sensor (see page 76).
Sensor temperature out of
range
Protect the sensor from extreme variations in
temperature. See the
Metrological characteristics
on page 92.
Summary of Contents for OLCT 80 d
Page 1: ...NPO80GB Revision F 1 OLCT 80 GAS TRANSMITTER USER MANUAL...
Page 10: ...OLCT 80 GAS TRANSMITTER USER MANUAL 4 NPO80GB Revision F 1...
Page 56: ...OLCT 80 GAS TRANSMITTER USER MANUAL 50 NPO80GB Revision F 1...
Page 78: ...OLCT 80 GAS TRANSMITTER USER MANUAL 72 NPO80GB Revision F 1...
Page 80: ...OLCT 80 GAS TRANSMITTER USER MANUAL 74 NPO80GB Revision F 1...
Page 86: ...OLCT 80 GAS TRANSMITTER USER MANUAL 80 NPO80GB Revision F 1...
Page 93: ...OLCT 80 GAS TRANSMITTER USER MANUAL NPO80GB Revision F 1 87...
Page 94: ...OLCT 80 GAS TRANSMITTER USER MANUAL 88 NPO80GB Revision F 1...
Page 96: ...OLCT 80 GAS TRANSMITTER USER MANUAL 90 NPO80GB Revision F 1...
Page 104: ...OLCT 80 GAS TRANSMITTER USER MANUAL 98 NPO80GB Revision F 1...
Page 115: ...OLCT 80 GAS TRANSMITTER USER MANUAL NPO80GB Revision F 1 109...