background image

Operator's Manual

Contents

Safety

1

Symbols

1

Precautions

1

Introduction

3

Requirements

4

Probe Kit

5

Standard Accessories

6

Voltage Derating for Standard Accessories

8

Specifications

9

Guaranteed Specifications

9

Environmental Characteristics

9

Common Mode Rejection Ratio

12

Input Voltage vs. Frequency and Burn Limit

13

Differential Mode and Common Mode

14

Differential Mode Range and Common Mode Range

14

Differential Input Impedance

14

Operation

15

Connecting to the Test Instrument

15

Connecting to the Test Circuit

15

Operating with an Oscilloscope

16

Maintenance

19

Cleaning

19

Calibration Interval

19

Service Strategy

19

Replacement Parts

19

Returning a Product for Service

20

Functional Test Procedure

21

Required Equipment

21

Test Procedure

21

Performance Verification

22

Required Equipment

22

Preliminary Procedure

23

Certification Procedure

23

923278-00

i

www.

GlobalTestSupply

.com

Quality Teledyne Lecroy Products Online at:

[email protected]

Summary of Contents for HVD3102

Page 1: ...Operator s Manual HVD3102 and HVD3106 High Voltage Differential Probes www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupply com...

Page 2: ...www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupply com...

Page 3: ...HVD3102 and HVD3106 High Voltage Differential Probes Operator s Manual June 2014 www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupply com...

Page 4: ...raged to distribute and duplicate Teledyne LeCroy documentation for their own internal educational purposes Teledyne LeCroy is a trademark of Teledyne LeCroy Inc Other product or brand names are trade...

Page 5: ...e and Common Mode Range 14 Differential Input Impedance 14 Operation 15 Connecting to the Test Instrument 15 Connecting to the Test Circuit 15 Operating with an Oscilloscope 16 Maintenance 19 Cleaning...

Page 6: ...age Differential Probes HVD3102 HVD3106 Test Record 25 Reference 26 Certifications 26 Warranty 29 Contact Us 30 Notes 31 ii 923278 00 www GlobalTestSupply com Quality Teledyne Lecroy Products Online a...

Page 7: ...AGE WARNING Risk of electric shock ESD CAUTION Risk of electrostatic discharge ESD that can damage the instrument if anti static measures are not taken Double Insulation Measurement Ground Precautions...

Page 8: ...source Comply with the voltage derating curve When measuring higher frequency signals comply with the Voltage vs Frequency Derating Curve Use only within the operational environment listed Do not use...

Page 9: ...e is supplied with a complete set of lead accessories and a soft accessory case The main differences between the two probes is the probe bandwidth 25 MHz vs 120 MHz The CMRR for the probes is exceptio...

Page 10: ...tenuation 50x or 500x is automatically selected based on oscilloscope gain range V div setting and the offset adjust is unified with that of the oscilloscope The sensitivity of the HVD31xx ranges from...

Page 11: ...rd accessories described below HVD3102 and HVD3106 Probe Kit See Replacement Parts for information about ordering replacement accessories Adobe portable document format PDF copies of this manual are a...

Page 12: ...ories they are meant to be used as a permanent installation in a test set up Safety Alligator Clips PK HVA 01 QTY 2 1 ea red black Designed to reliably grip large components such as bus bars and large...

Page 13: ...grab leads pins and wires up to 4 mm 0 157 inch in diameter Insulated 1000 V CAT II Plunger Alligator Clips PK HVA 04 QTY 2 1 ea red black The clip is designed to securely grasp thick wires cables gr...

Page 14: ...CAUTION The operating altitude of the HVD3102 and HVD3106 is derated to 2000 m 6560 ft when used with the accessories above WARNING The voltage and CAT rating of the probe are derated to the values in...

Page 15: ...0 90 14 ns 2 9 ns CMRR Test Limits 23 C 80 db 50 Hz 60 db 1 MHz 80 db 50 Hz 60 db 1 MHz Environmental Characteristics Temperature Operating 0 C to 50 C Temperature Non operating 40 C to 70 C Relative...

Page 16: ...2 and HVD3106 High Voltage Differential Probes HVD3102 Typical Bandwidth HVD3106 Typical Bandwidth 10 923278 00 www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupp...

Page 17: ...Operator s Manual HVD3102 Typical CMRR Performance HVD3106 Typical CMRR Performance 923278 00 11 www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupply com...

Page 18: ...etween the and input paths Obtain high CMRR values by precisely matching the input attenuators in a differential amplifier The matching includes the DC attenuation and the capacitance which determines...

Page 19: ...ng the probe to active signals above this burn limit could result in injury to the operator WARNING To avoid risk of electric shock or fire comply with the burn limits of the derating curve when measu...

Page 20: ...the maximum signal that can be applied between the and inputs without overloading the amplifier which otherwise would result in clipping or distorting of the waveform measured by the oscilloscope The...

Page 21: ...are available at the probe tip to connect the probe to a circuit under test For accurate measurements both the and inputs must be connected to the test circuit Positive voltages applied to the input...

Page 22: ...C while the probes are stacked and in operation The exceptional CMRR performance of the probe should prevent interference between probes when they are stacked but care should be taken to separate the...

Page 23: ...r that V div setting Then the maximum offset available with the probe and oscilloscope combination can be calculated as follows Max Positive Offset Available Max Positive Offset Probe and Oscilloscope...

Page 24: ...ding on the measurement accuracy desired and or the change in the ambient temperature where the probe is located it may be necessary to perform Auto Zero more often If the probe is disconnected from t...

Page 25: ...er all servicing to qualified personnel A defective probe under warranty will be replaced with a factory refurbished probe A probe that is not under warranty can be exchanged for a factory refurbished...

Page 26: ...the owner l Product model and serial number l Description of failure or requisite service 4 Pack the product case in a cardboard shipping box with adequate padding to avoid damage in transit 5 Mark th...

Page 27: ...e black clip to the ground post of the CAL out signal For oscilloscopes with the CAL signal on a BNC connector a BNC to Banana adapter e g Pomona model 1296 may be used 6 Press AUTOSETUP 7 Set the sen...

Page 28: ...and models of test instruments additional adapters or cables may be required Only the parameters listed in boldface in the Minimum requirements column must be calibrated to the accuracy indicated Des...

Page 29: ...function generator output to the DMM using a BNC cable and a female BNC to dual banana plug adapter 4 Adjust the function generator output voltage until the DMM reads 7 000 V 0 01 V 5 Record the DMM...

Page 30: ...the oscilloscope scale factor to 5 V Div 16 Record the DMM reading to 0 01 mV resolution in the Test Record 17 Multiply the measured output voltage recorded in step 16 by the actual probe attenuation...

Page 31: ...he limit check under Intermediate Results Serial Number Asset Tracking Number Date Technician Equipment Model Serial Number Calibration Due Date Oscilloscope Digital Multimeter Function Generator1 1 T...

Page 32: ...A1 2010 Radiated and Conducted Emissions Group 1 Class A 1 2 Electromagnetic Immunity EN 61000 4 2 2009 Electrostatic Discharge 4 kV contact 8 kV air 4 kV vertical horizontal coupling planes EN 61000...

Page 33: ...f the European Communities EN 61010 031 2002 A1 2008 Safety requirements for electrical equipment for measurement control and laboratory use Part 031 Safety requirements for hand held probe assemblies...

Page 34: ...6 EC and 2006 66 EC on Waste Electrical and Electronic Equipment WEEE and Batteries The product is subject to disposal and recycling regulations that vary by country and region Many countries prohibit...

Page 35: ...to do this we must first examine the product and find that it is defective due to workmanship or materials and not due to misuse neglect accident or abnormal conditions or operation Teledyne LeCroy sh...

Page 36: ...zers Ph 44 12 765 03971 Singapore Oscilloscopes Teledyne LeCroy Singapore Pte Ltd Blk 750C Chai Chee Road 02 08 Technopark Chai Chee Singapore 469003 Ph 65 64424880 FAX 65 64427811 Singapore Protocol...

Page 37: ...Operator s Manual Notes 923278 00 31 www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupply com...

Page 38: ...HVD3102 and HVD3106 High Voltage Differential Probes 32 923278 00 www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupply com...

Page 39: ...www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupply com...

Page 40: ...www GlobalTestSupply com Quality Teledyne Lecroy Products Online at sales GlobalTestSupply com...

Reviews: