Frontline Harmony Hardware & Software User Manual
28
HCI/DSU/BV-05-C
Reset in initiating state
HCI/DSU/BV-06-C
Reset to master
HCI/GEV/BV-01-C
Verify that for each controller supported in the IUT, every HCI command not
supported yields a Command Complete event with status Unknown HCI
Command in return
HCI/GEV/BV-02-C
Verify that each supported legacy and extended scanning command yields a
command complete event with status 'Command Disallowed' in return when
sent after a command of the other type
HCI/GEV/BV-03-C
Verify that each supported legacy and extended scanning command yields a
Command Complete event with status ‘Command Disallowed’ in return
when sent after a command of the other type
HCI/GEV/BV-04-C
Verify that each specified extended advertising command yields a Command
Complete event with status ‘Command Disallowed’ in return when sent with
no scan response data
HCI/HFC/BV-04-C
LE Set Event Mask
4.1.2 Link Layer
The Harmony software provides 484 Link Layer tests (Table 4.2). To run LL tests, expand the LL Test
Suite to select one or more specific tests, or you may select Test Suite – LL to run all Link Layer tests.
Table 4.2 – Link Layer Tests
Test
Description Summary
LL/CON/ADV/BI-01-C
Connection Supervision Timeout During Fail Connection Setup
LL/CON/ADV/BV-01-C
Accepting Connections
LL/CON/ADV/BV-02-C
Accepting Connections Timeout
LL/CON/ADV/BV-03-C
ADVERTISING/MASTER - Master Packets
LL/CON/ADV/BV-04-C
Tests that an advertiser IUT upon receiving a connection indication to the
directed advertising indications stops advertising after the reception and
starts to maintain a connection in the slave role
LL/CON/ADV/BV-05-C
Extended Advertising, Accepting Connections – LE 1M PHY
LL/CON/ADV/BV-06-C
Tests that an advertiser IUT using undirected connectable advertising with
legacy PDUs receives a connection indication on the primary channel stops
advertising after the reception and starts to maintain a connection in the
slave role
LL/CON/ADV/BV-07-C
Tests that an advertiser IUT receives a connection request stops advertising
after the reception and starts to maintain a connection in the slave role
when the connection request indicates no support for Channel Selection
Algorithm #2
LL/CON/ADV/BV-08-C
Tests that an advertiser IUT receives a connection request to the directing
advertising indication stops advertising after the reception and starts to
maintain a connection in the slave role when the connection request
indicates no support for Channel Selection Algorithm #2
LL/CON/ADV/BV-09-C
Tests that an advertiser IUT receives a connection request stops advertising
after the reception and starts to maintain a connection in the slave role
Summary of Contents for FrontLine Harmony
Page 1: ...Harmony Test System User Manual...
Page 7: ...Frontline Harmony Hardware Software User Manual 7 Figure 1 1 Installed Applications Detected...
Page 25: ...Frontline Harmony Hardware Software User Manual 25 Figure 3 5 IUT Information...
Page 55: ...Frontline Harmony Hardware Software User Manual 55 Figure 5 4 Testing Summary...