background image

I n p u t s   f o r  

r a i n

,  

w i n d

  a n d 

temperature

 (for ice) sensors. 

Combination of rain and temperature 

sensors to detect 

snow

.

Self-learning procedure for

 limit switches

 and 

working times

.

LED CARD

 (optional) to control the 

1-colour

RGB

 or 

RGBW

 24V

 

LED lights.

Independent

 or 

synchronized

 control of motor outputs. 

Product code

M

24Vdc

/

M

24Vdc

M

24Vdc

M

24Vdc

M

24Vdc

24Vdc

M

230Vac

230

Vac

M

230Vac

M

230Vac

M

230Vac

230

Vac

24Vdc

24Vdc

M

230Vac

/

230

Vac

M

230Vac

M

230Vac

M

24Vdc

TVPLA868CC2(S)

 

(h = 74mm)  

TVPLA868CC2B(S)

 

(h = 50mm)

EN - 24V

 CONTROL UNIT WITH RADIO RECEIVER TO CONTROL ONE OR 

TWO 24V MOTORS FOR ADJUSTABLE SLATS

TELECO AUTOMATION SRL  

Via dell’Artigianato, 16 - 31014 Colle Umberto (TV)  ITALY
TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com

This document is the property of  Teleco Automation Srl who reserves all reproduction and copying rights

 

DOC.: T569.16_EN

TVPLA868CC2(S)-CC2B(S)

DATE: 06/04/18

Summary of Contents for TVPLA868CC2

Page 1: ... M 24Vdc 24Vdc M 230Vac 230 Vac M 230Vac M 230Vac M 230Vac 230 Vac 24Vdc 24Vdc M 230Vac 230 Vac M 230Vac M 230Vac M 24Vdc TVPLA868CC2 S h 74mm TVPLA868CC2B S h 50mm EN 24V CONTROL UNIT WITH RADIO RECEIVER TO CONTROL ONE OR TWO 24V MOTORS FOR ADJUSTABLE SLATS TELECO AUTOMATION SRL Via dell Artigianato 16 31014 Colle Umberto TV ITALY TELEPHONE 39 0438 388511 FAX 39 0438 388536 www telecoautomation c...

Page 2: ... sure that the sensors and motors are correctly connected A faulty connection of the motors polarity inversion could damage them together with the connected mechanical elements The power supply must supply the required voltage and current according to the characteristics of the system The power supply must be compliant with IEC60950 1 and must be protected against the short circuit and over voltag...

Page 3: ...rent absorption over the threshold Eight quick flashes Safety limit switch Ten quick flashes One motor is short circuited One flash every 2 s Rain sensor is deactivated One flash every 3 s Temperature sensor is deactivated L5 RED ON Power ON Optional LED CARD only in TVPLA868CC2 S version Memory 10AFuse 24V Power supply RAIN sensor WIND sensor Aerial TEMP Sensor ATTENTION The electronic board is p...

Page 4: ...NOT change the DIP configuration This change would be signalled by a new intermittent sound and the flashing of L3 and would require a new configuration procedure 2 1 L1 L1 Closing Opening M 24Vdc Check that movement stops when the limit switch is reached L1 ON If it doesn t change the threshold as per PAR 2 4 page 7 and repeat LIMIT SWITCHES CLOSE OPEN DIRECTION P1 P2 If the direction is wrong in...

Page 5: ... time for 5 s DO NOT change the DIP configuration This change would be signalled by a new intermittent sound and the flashing of L3 and would require a new configuration procedure L1 L2 L1 L2 Closing Opening M 24Vdc Check that movement stops when the limit switches are reached L1 and L2 ON If it doesn t change the threshold as per PAR 2 4 page 7 and repeat LIMIT SWITCHES CLOSE OPEN DIRECTION P1 P2...

Page 6: ...t stops when the limit switch is reached L1 ON If it doesn t change the threshold as per PAR 2 4 page 7 and repeat LIMIT SWITCHES CLOSE OPEN DIRECTION P1 P2 If the direction is wrong invert the motor wires L2 L2 Closing Opening M 24Vdc Check that movement stops when the limit switch is reached L2 ON If it doesn t change the threshold as per PAR 2 4 page 7 and repeat LIMIT SWITCHES CLOSE OPEN DIREC...

Page 7: ...ly ended and the threshold remains unchanged ATTENTION at the end of the procedure DIP6 must be set to OFF and remain in that position during standard operation of the control unit SETTING OF THE CURRENT THRESHOLD DURING CONFIGURATION DIP6 ON 10 s 30 s P1 DIP6 OFF L4 flashes 2 4 3 SELF LEARNING OF LIMIT SWITCHES MOTOR 1 first then MOTOR 2 ATTENTION ON 1 2 3 4 5 6 Press P1 and P2 simultaneously twi...

Page 8: ... hold to run C 7 42 CHANNEL TRANSMITTER AUTOMATIC COMMANDS 2 or 3 BUTTONS HOLD TO RUN COMMANDS 2 or 3 BUTTONS CH5 CH6 CH7 Open STOP Close 3 18 channel transmitter CH5 CH6 CH7 Open hold to run Close hold to run STOP Open STOP Close STOP Open hold to run Close hold to run 2 channel transmitter D GREEN MOUSE SCREEN 1 Light sensor 2 OPEN button 3 CLOSE button 1 4 5 2 3 6 4 Light level memorization but...

Page 9: ...ype of desired memorization and hold the last time The buzzer emits a continuous sound Press the button of the transmitter relative to the code to be memorized Successful memorization is indicated by the intermittent sound of the buzzer TYPE OF MEMORIZATION see description page 8 P1 or P2 A 7 42 CHANNEL TRANSMITTER 2x Press any button of the 7 42 channel transmitter B AUTOMATIC COMMANDS 2 or 3 BUT...

Page 10: ...d radio code will have the same functions as the code used for memorization This procedure is compatible with any type of transmitter Press button P3 of the memorized transmitter and hold The buzzer emits a continuous sound Press a button relative to an already memorized code The buzzer stops for 1 second and then starts the continuous sound again Press the button relative to the new code to be me...

Page 11: ...run commands The measured temperature is above 3 C or rain is no longer detected L4 The temperature sensor NTC 10K 3435K activates whenever there is danger of ice forming TEMPERATURE sensor 1 1 4 3 Factory setting DEACTIVATED TEMPERATURE Alarm priority MEDIUM ALARM ACTIVATED when What happens with ALARM ACTIVATED ALARM NOT ACTIVE when The measured temperature is below 2 C and the slats are closed ...

Page 12: ...y execute hold to run commands thereby exiting from the alarm status RAIN sensor 1 1 4 4 Factory setting ACTIVATED Alarm priority LOW RAIN L4 ACTIVATION only if the sensor is connected DEACTIVATION 7x Activation deactivation of the RAIN sensor by means of the transmitter Deactivation Press the STOP button of a memorized 7 42 or 3 channel transmitter for 10 s The buzzer emits 2 beeps L4 flashes onc...

Page 13: ... complete closing complete closing Put the slats to the desired angle then 5 s desired position The buzzer will make a beep each time the button is pressed According to the motor control mode 1 s continuous sound 2 s 3 s continuous sound continuous sound Press P1 or P2 as many times as required by the type of desired memorization and hold the last time The buzzer emits a continuous sound complete ...

Page 14: ...2 Replacing the control unit Memory 5 3 Quick learning of limit switch If the following have been already programmed motor control mode the correct motor direction at least one transmitter for each of the independent motor output current threshold to be applied it is possible to carry out the self learning of limit switches without accessing the control unit complete closing complete opening compl...

Page 15: ...cy 868 3 MHz Radio memory capability transmitters 16 Rain sensor power supply 12 Vdc max 100mA Anemometer 4 pulses rotation ANEM4 Temperature probe NTC R 10Kohm B 3435K Protection rating IP54 Material of the box and its cover Not suitable for direct UV exposure Thermoplastic ABS TVPLA868CC2 S TVPLA868CC2B S TVPLA868CC2 S TVPLA868CC2B S Sensors Power supply M1 M2 4 wires cable Power supply M1 M2 LE...

Page 16: ...60W per output LED CARD to control the 1 colour RGB or RGBW 24V LED lights optional only in TVPLA868CC2 S version RAIN102 RAIN sensor TMP150 TEMPERATURE sensor ATTENTION Maximum power of the system motors and lights is 240W TELECO AUTOMATION S R L ITALY Tel 39 0438 388511 info telecoautomation com TELECO AUTOMATION FRANCE FRANCE Tel 33 0 472 145080 info telecofrance com TELECO AUTOMATION GMBH GERM...

Reviews: