Model 458-AWGN2 Dual Output AWGN Generator Line Module 

Page 3-3   

3.2 Graphical 

User 

Interface 

 

Refer to the 458 Universal Graphical User Interface Reference Manual for more information.  

 
3.3 LCD 

Display 

 

Step One 
 

  Select the slot in the 458-3SLx (3-Slot) Chassis or 458-CC16/458-CM (16-Slot) Chassis 

using the UP or DOWN arrows on the LCD display (e.g., when using our 3-slot chassis: slot 
1 top, slot 2 middle, slot 3 bottom). 
 

Step Two 
 

  Use Up arrow to select the CO or CPE noise. 

  Adjust the noise level using LEFT and RIGHT arrow buttons.  

 

Summary of Contents for 458-AWGN2

Page 1: ...Model 458 AWGN2 Dual Output AWGN Generator Line Module Rev Date of Publication 04 15 11 Results You Can Count On...

Page 2: ...ian Noise AWGN on the CO and or CPE side of a loop simulator installed in one of Telebyte s chassis or onto real cable Contact Information Telephone E mail Internet General 631 423 3232 support teleby...

Page 3: ...EBYTE INC warrants its broadband simulation equipment to be free from defects in material and workmanship under normal and proper use and in its unmodified condition for 12 months starting on the date...

Page 4: ...will have a 90 day warranty In those cases where no trouble is found a reduced charge will be billed to cover handling testing and packaging Whether in or out of warranty a Return Material Authorizati...

Page 5: ...n 1 1 2 0 Specifications 2 1 2 1 458 AWGN2 2 1 2 2 458 3SLB 2 1 2 3 458 CC 16 458 CM 2 2 3 0 Control 3 1 3 1 1 RS 232 Serial Port Remote Commands 3 1 3 1 2 GPIB Remote Command 3 2 3 2 Graphical User I...

Page 6: ...sis where settings are controlled by a convenient keypad located on the front RS 232 Ethernet or IEEE 488 GPIB The modular design of Telebyte s products allows the 458 AWGN2 to be combined with other...

Page 7: ...s on front 2 for CO side 2 for CPE side of loop 2 2 458 3SLB Product Specifications Chassis and Control Module Controls Keypad for setting loop lengths and IEEE 488 address RS 232 or Ethernet communi...

Page 8: ...0 VAC 50 or 60 Hz Size 7U 19 in W x 22 in D x 12 22 in H 482 6 mm W x 558 8 mm D x 310 4 mm H Environmental Operating 32 F to 122 F 0 to 50 degrees C Storage 0 to 95 relative humidity non condensing R...

Page 9: ...ion 3 1 Remote Commands 3 1 1 RS 232 Serial Port Remote Commands Set Noise Mode Level Command Values SL M NOISE CPE V or SL M NOISE CO V Where SL set length M module slot number 01 16 458 CM or 01 03...

Page 10: ...D LENGTH 02 NOISE CPE 123 75 Set CPE noise source to 123 75 dBm Hz SETCARD LENGTH 02 NOISE CO 95 00 Set CO noise source to 95 00 dBm Hz SETCARD LENGTH 02 NOISE CPE OFF Set CPE noise source to off SETC...

Page 11: ...l for more information 3 3 LCD Display Step One Select the slot in the 458 3SLx 3 Slot Chassis or 458 CC16 458 CM 16 Slot Chassis using the UP or DOWN arrows on the LCD display e g when using our 3 sl...