background image

  

 

Wireless Smoke 

Detector  

RM-LES900 

 

 

Wireless Smoke Detector RM-LES900 

Page 4/7 

2.2  Function 

The device only functions when fully assembled. The smoke detector head will not 
function without the radio base.  Each device has a unique identification code. If 
using multiple Wireless Smoke  Detectors, the Carephone  can differentiate them 
through their code. 

2.3  Permit documents, certificates, declaration  

The Wireless Smoke Detector RM-LES900 conforms to: 

  EMC Directive (2014/30/EU) 

  Low Voltage Directive (2014/35/EU) 

  RED Directive (2014/53/EU) 

  RoHS Directive (2011/65/EU) 

  EN62368 Safety Standard 

  EN14604 Smoke Alarm Device Standard 

2.4  Technical Data 

  Radio Mounting Base  

 
Dimensions (H × ØB) 

22 × 86mm 
52g 

Weight 

 

Material housing 

PC/ABS 

Colour  

White, similar to RAL 9003 

Operating temperature 

+4°  to +38°C  

Storage temperature 

-20°  to +60°C  

Max. humidity  

90% (non-condensing) 

Battery 

CR 1/2AA – Varta 3.6V Lithium,  
interchangeable, polarity indicated in  
the overview of components 

Protection class 

III (EN 60730-1; SELV) 

Ingress protection 

IP 30 (EN 60529) 

 
 
 

Summary of Contents for RM-LES900

Page 1: ...ill sound Make sure the connection between the wireless smoke detector and the TeleAlarm Carephone is working Trigger a test alarm by pressing the smoke detector head CAUTION Danger of explosion and fire Replacing the battery by an incompatible type or inserting it with reversed polarity can cause excessive heat fire or explosion Danger of hearing loss The Wireless Smoke Detector generates a very ...

Page 2: ... improper transport and storage Only transport in the original packaging During storage and transportation the specified ambient conditions must be maintained The devices must be protected from impact when stored and during transport Failure to heed these instructions can lead to damage that does not fall under guarantee and warranty ...

Page 3: ...Wireless Smoke Detector RM LES900 Wireless Smoke Detector RM LES900 Page 3 7 2 Product Description 2 1 Overview of Components base plate radio mounting base assembly ...

Page 4: ...s Smoke Detector RM LES900 conforms to EMC Directive 2014 30 EU Low Voltage Directive 2014 35 EU RED Directive 2014 53 EU RoHS Directive 2011 65 EU EN62368 Safety Standard EN14604 Smoke Alarm Device Standard 2 4 Technical Data Radio Mounting Base Dimensions H ØB 22 86mm 52g Weight Material housing PC ABS Colour White similar to RAL 9003 Operating temperature 4 to 38 C Storage temperature 20 to 60 ...

Page 5: ... low battery A brief tone sounds and the red LED blinks every 48 seconds When this display starts the smoke detector s alarm head can still be operated for 30 days or emit an alarm for 4 minutes when triggered Normal operation The red LED blinks every 48 seconds Fire alarm Three tones one after the other LED blinks every 0 5 seconds Sound pressure level 85dB 3m LED display Fire alarm Increased sam...

Page 6: ...nd screws When mounting pay attention to the composition of the ceiling and the suitability of the enclosed mounting materials Select an installation site on the ceiling on which secure mounting is possible Turn the radio mounting base on the base plate to lock it in place The smoke detector head must be inserted into the radio mounting base taking the coding bar and locked into place by turning i...

Page 7: ...ector head 1 The bayonet catch between the smoke detector head and the radio mounting base must be loosened 2 The smoke detector head should be disposed of as described in section 6 3 The new smoke detector head should be twisted into place in the radio mounting base with the assistance of the bayonet catch until it audibly locks in place 6 Decommissioning and Disposal The product must be disposed...

Reviews: