4.4 RST Button

The Regesta Smart PLC has a button that can be accessed from the outside and is labeled “RST”. It is located on
the connectors panel and has two functions.

• To trigger a reboot.

• To restart the device with the default configuration. The default configuration has IP 192.168.1.1 assigned to all

switch ports.

The external button is physically protected so it cannot be accidentally pushed. You need a sharp-pointed object to
activate it.

4.4.1 Restarting the device

Carry out the following steps to restart the device:

(1)

Press the RST button. Device restart is indicated by the S,C and L LEDs in off state and the ON LED lighting in
green.

(2)

Stop pressing the RST button as soon as the S, C and L LEDs go to off state.

(3)

The device will begin the restart with LEDs S and C off and LEDs L and ON in green.

4.4.2 Default Configuration

By following these steps, the RST button allows you to boot the device with its default configuration:

(1)

Press the RST button. Device restart is indicated by the S,C and L LEDs in off and the ON LED lights up in
green.

(2)

Keep pressing the RST button. The S LED flashes green and the L LED lights up in green while you are still
pressing the RST button. This state indicates the device configuration has changed to the default configuration.

(3)

Stop pressing the RST button to allow the device to restart.

(4)

The device will begin the restart with LEDs S and C off and LEDs L and ON in green.

(5)

As the device now has the default configuration, you can access it through the IP (bearing in mind that the de-
fault address for the equipment is 192.168.1.1 and that it is accessible from any switch port).

4.5 Troubleshooting

The following table can help you solve problems when installing the device. If you cannot solve the problem, contact
your dealer for more information.

Symptom

Solution

No LED lights up on the router.

Check the power supply to the router (power source, main power outlet).

The local console does not re-
spond.

Check the console cable is the right one and it is connected to the device and the
asynchronous terminal.

Teldat S.A.

4 Connecting the router

Regesta Smart PLC

25

Summary of Contents for Regesta Smart PLC

Page 1: ...Regesta Smart PLC Installation Manual Copyright Teldat dm339 I Version 1 0 11 2019 Teldat S A Teldat S A Manual Regesta Smart PLC 1 ...

Page 2: ...at S A offers no warranty whatsoever for information contained in this manual Teldat S A is not liable for any direct indirect collateral consequential or any other damage connected to the deliv ery supply or use of this manual Manual Teldat S A 2 Regesta Smart PLC ...

Page 3: ...view 5 2 1 General Description 5 2 2 Device Models 6 2 3 Hardware Features 6 2 4 Components 7 2 4 1 Front Panel 7 2 4 2 Connector Panel 9 2 4 3 Underside Panel 11 2 5 Power Supply 11 Chapter 3 Installing the Router 12 3 1 Workplace Conditions 12 3 2 Removing Installing the Connector Protector 12 3 3 Installing a DIN rail mount accessory 14 3 4 Wall mounting 15 Chapter 4 Connecting the router 17 4 ...

Page 4: ...rer Information 29 5 2 Intended use of the equipment 29 5 3 EC Declaration of Conformity No Radio version 29 5 4 EC Declaration of Conformity Radio version 30 5 5 CE Marking 30 5 6 National Restrictions 30 5 7 Operating Frequency 30 5 8 REACH 30 5 9 WEEE Information 31 Appendix A Technical Information 32 A 1 Connectors 32 A 1 1 LAN Connector 32 A 1 2 WAN Base T Connector 32 A 1 3 WAN SFP Connector...

Page 5: ...terface 35 A 2 7 Configuration Interface 36 A 2 8 RS 232 Serial Interface 36 A 2 9 RS 485 Serial Interface 36 A 2 10 Power Supply Specifications 36 A 2 11 Dimensions and weight 36 A 2 12 Environmental Specifications 36 Appendix B Radio Information 37 B 1 RF WWAN Specifications 37 Teldat S A Table of Contents Regesta Smart PLC iii ...

Page 6: ...is manual This installation guide contains the following information A description of the available features in the Regesta Smart PLC Technical specifications Power supply requirements A description of the device LEDs and connectors Troubleshooting 1 5 What is not in this manual This document does not contain information about the device software or its configuration For information on how to conf...

Page 7: ...1 8 Safety Warnings Connecting 1 Disconnecting 1 0 1 0 1 2345 144 4 67 2 8 9 1 4226 2345 144 4 67 2 8 9 1 4226 1 About This Manual Teldat S A 2 Regesta Smart PLC Connecting 1 Disconnecting 1 ...

Page 8: ... 0 A 9 0 8 14 9 8 8 B A 00 8 14 8 8 0 1 0 0 C 1 D A 4 27 1E2446 0 A 0 1 C 1 D A 4 27 1E2446 A 9 8 A 8 A 8 8 F Teldat S A 1 About This Manual Regesta Smart PLC 3 ...

Page 9: ...m781 I Cellular Interface Teldat Dm748 I Software Updating Teldat Dm823 I PLC Gateway 1 10 Technical Support Contact information Web http www teldat com Tel 34 918 076 565 Fax 34 918 076 566 Email support teldat com 1 About This Manual Teldat S A 4 Regesta Smart PLC ...

Page 10: ...ain communication method is a TCP transport layer for DLMS with extensions for optimally multi plexing IEC 61334 4 32 connections also known as Ticket 67 over a Wireless WAN WWAN data network on private or public networks or a LAN connection The number of smart meters controlled depends on the license Thanks to its modular design this device can quickly adapt to the latest WWAN technologies The Re...

Page 11: ...red 110 240 VAC RWRTHR2LAC PLC Regesta Smart PLC 1 LAN Gigabit Ethernet port 1 WAN Combo Gigabit Ether net port 1 RS232 1xWWAN Bands LTE 1 3 5 7 8 20 38 40 41 WCDMA 1 5 8 AC powered 110 240 VAC 2 3 Hardware Features The following lists the hardware platform features for the Regesta Smart PLC router External Power Input Terminal Block 2 Poles 5 08 mm pitch connector AC Power Nominal 110 240 VAC Abs...

Page 12: ...g on the model L models 1xLTE Category 4 WWAN module with two SMA connectors 2 Intenal SIM trays with 2FF form factor External Reset Recovery push button 2 4 Components 2 4 1 Front Panel The front panel includes the status LEDs The following figure shows the front panel Fig 3 Front Panel While the device is in startup mode LED L lights up in green Once the device has started up the LEDs indicate t...

Page 13: ...ular interface corresponding to the active SIM Off Red Amber Green Cellular interface is not active Coverage level below 100dBm Coverage level between 90dBm and 100dBm Coverage level above 90dBm LAN Ethernet LAN inter face Off Green Ethernet LAN is disabled or connection is not established Ethernet connection link established Steady Data is not being transferred Flashing Data is being transferred ...

Page 14: ...32 asynchronous DCE serial port For more information about the CONF connector refer to Console Connector as Serial Port CONF connector on page 22 Configuration Connector on page 33 Configuration Interface on page 36 C WAN Gigabit Ethernet SFP connector For more information about the WAN interface with SFP connector refer to WAN connections on page 19 Teldat S A 2 Product Overview Regesta Smart PLC...

Page 15: ...t the PLC connection options refer to PLC connection on page 20 PRIME PLC Interface on page 34 G DCE RS 232 serial ports or RS 485 2 4 wires RS 422 The type of configuration of each port depending on the hardware configuration of the device model For more information on the connector for serial ports 2 4 wire RS 485 RS 422 and RS 232 DCE refer to RS232 option RS 232 Serial Port on page 23 RS 232 S...

Page 16: ...Panel The following elements can be found on the underside panel Table 4 Underside Panel elements table Item Description A Slots for fixing accessories used to attach the device to a DIN rail mount For fur ther information on this accessory please see section Wall mounting on page 15 B Platform where the label containing product information is placed This label con tains information on the device ...

Page 17: ... The Regesta Smart PLC includes a protective case for connectors The main function of the protective case is to provide protection against accidental electric shock by preventing direct contact with the connectors while the device is in operation Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit To remove the protective case ...

Page 18: ...Slide the case up as shown below Teldat S A 3 Installing the Router Regesta Smart PLC 13 ...

Page 19: ...ou apply power to the device 3 3 Installing a DIN rail mount accessory The Regesta Smart PLC can be installed on a standard DIN rail A special kit is required to mount the device on the DIN rail This kit is included with delivery of the device The DIN rail kit allows the device to be installed in different positions The kit contains 2 screws for fixing the rail mount to the device The holes on the...

Page 20: ...C can be mounted on a wall thanks to three holes To ensure it is properly fastened screws must be inserted in said holes Before mounting the device on the wall remove the protective case The following image shows where the fastening holes are located Teldat S A 3 Installing the Router Regesta Smart PLC 15 ...

Page 21: ...Fig 13 Holes for wall mounting 3 Installing the Router Teldat S A 16 Regesta Smart PLC ...

Page 22: ...ton on page 25 Troubleshooting on page 25 Updating the software on page 26 4 1 Power Source Note Please read the following instructions carefully before connecting the router 4 1 1 Power Connector pins The power connector is located on the connector panel Fig 14 Power Supply Connector The power connector on this router is a 5 08 mm pitch 2 wire terminal block There is no assignation for Phase and ...

Page 23: ...ing and premature aging prob lems of drivers and other components 4 1 3 Connecting Ensure that the power supply is NOT connected to either the electricity supply or the router Connect all data cables Connect the power supply cable to the device Install the protective case for connectors Connect the power supply cable to the electricity supply 4 1 4 Disconnecting Disconnect the power supply from th...

Page 24: ...tion This port has 2 connect ors SFP for an optical link and RJ 45 for a 10 100 1000 Base T link but they cannot work simultaneously Please pay careful attention to the labeling to avoid mistaking this port for other types of ports Fig 16 WAN and SFP connectors Teldat S A 4 Connecting the router Regesta Smart PLC 19 ...

Page 25: ...h the IEC EN 60825 1 2007 standard 4 2 3 PLC connection The Regesta Smart PLC incorporates a Power Line Communication PLC interface This interface allows the device to communicate with several compatible PLC devices through the power line PLC signal injection is made inside the device through the power supply connector There is a LED labeled P to indicate the connection state Fig 18 PLC and Power ...

Page 26: ...ientation its location with respect to other wireless devices and radiation devices such as communication devices personal computers etc can significantly influence device performance Antennas transmit and receive radio signals Performance is also affected by environmental factors such as distance between the device and the base station physical obstacles and other interferences due to radio frequ...

Page 27: ...wo RJ45 connectors labeled as Serial may be inoperative 4 2 5 1 Console Connector as Serial Port CONF connector It s possible to convert the console port into an RS 232 asynchronous DCE serial port This port has the following characteristics ation Connector on page 33 for more information about pin assignment 5 RJ45 connector Fig 20 Console connector 4 2 5 2 Asynchronous Serial Ports The Asynchron...

Page 28: ... device s protective case and are labeled SIM1 and SIM2 In installations where only one SIM card is required we recommend installing it in the main SIM1 tray Warning Never install the SIM cards when the device is switched on Always disconnect the device from the main power supply before installing the SIM cards Always disconnect the device before removing the connectors protective casing to access...

Page 29: ... socket 2 Fig 22 Location of the SIM1 and SIM2 trays 4 3 2 Procedure to install the SIM Once the appropriate SIM is selected carry out the following steps 1 Push the fastening in the direction indicated by the arrow with the word OPEN 2 Open the upper part of the tray 3 Fully insert the SIM card using the guides the SIM s notch must be on the right side as shown 4 Return the tray to its original p...

Page 30: ...ration 1 Press the RST button Device restart is indicated by the S C and L LEDs in off and the ON LED lights up in green 2 Keep pressing the RST button The S LED flashes green and the L LED lights up in green while you are still pressing the RST button This state indicates the device configuration has changed to the default configuration 3 Stop pressing the RST button to allow the device to restar...

Page 31: ...dated to new releases Please contact your distributor for further details on new releases There are various ways to update one of our routers For further information please see manual Dm 748 I Software Updating The software required to update one of our routers is supplied in a format known as distribution This consists of a single file which contains all the files needed to update your device as ...

Page 32: ...on 4 6 1 2 Connecting through an IP terminal LAN connector The Regesta Smart PLC includes a default configuration that activates if you haven t preconfigured anything The router s default configuration establishes the following IP address and access mask IP address 192 168 1 1 IP mask 255 255 255 0 Note Some devices leave the factory with customized settings This personalization can mean that the ...

Page 33: ...from the IP terminal to IP address 192 168 1 1 Regesta Smart PLC default address The default configuration does not ask for credentials user password to ac cess the console 4 Connecting the router Teldat S A 28 Regesta Smart PLC ...

Page 34: ...Hereby Teldat S A declares that telecommunications equipment Regesta Smart PLC complies with Directive 2014 30 EU EMC Directive 2014 35 EU LVD Directives 2011 65 EU and 2015 863 EU RoHS of the European Parliament and of the Council Spanish ES Español Por la presente Teldat S A declara que el tipo de equipo de telecomunicaciones Regesta Smart PLC es conforme con Directiva 2014 30 UE EMC Directiva 2...

Page 35: ...cedures and marking 5 6 National Restrictions In accordance with Article 10 of 2014 53 EU we inform you that national restrictions and requirements may apply when it comes to authorization These can evolve with time Teldat S A recommends that you check with local au thorities what the latest status of national regulations is 5 7 Operating Frequency For the operating frequencies working in the devi...

Page 36: ...ste disposal facility at the end of its useful service life El símbolo del contenedor con la cruz que se encuentra en el aparato significa que cuando el equipo haya llegado al final de su vida útil deberá ser llevado a los centros de recogida previstos y que su tratamiento debe estar separado del de los residuos urbanos Teldat S A 5 Compliance Regesta Smart PLC 31 ...

Page 37: ...DA BI DA BI DB BI DB BI DA BI DA BI DB BI DC BI DC BI DB BI DD BI DD A 1 2 WAN Base T Connector RJ45 WAN RJ45 PIN FE Signals GE Signals 1 2 3 4 5 6 7 8 BI DA BI DA BI DB BI DB BI DA BI DA BI DB BI DC BI DC BI DB BI DD BI DD A 1 3 WAN SFP Connector SFP Standard SFP connector Technical Information Teldat S A 32 Regesta Smart PLC ...

Page 38: ...alled SMA Female PIN ANT Internal External RF in out GND A 1 5 Configuration Connector RJ45 CONFIGURATION PIN CONF 1 2 3 4 5 6 7 8 RxD GND GND TxD A 1 6 RS 232 Serial Port Connectors RJ45 PIN SERIAL 1 2 3 4 5 6 7 8 RTS DTR TxD GND CD RxD DSR CTS Teldat S A Technical Information Regesta Smart PLC 33 ...

Page 39: ...C Interface PROTOCOL PRIME 1 3 6 and PRIME 1 4 depending on the firmware uploaded ROLE Base Node COMMUNICATIONS Single phase injection PRIME 1 3 CENELEC A band PRIME 1 4 Multiband CENELEC FCC and ARIB bands TECHNOLOGY MicroChip ATPL360 chipset CONNECTOR Terminal Block 2 Poles 5 08 mm pitch is the same as power supply A 2 3 LAN Interface PROTOCOLS Ethernet 802 3 PORTS 1 port with MDI MDX auto detec...

Page 40: ...X LH single mode 1310 nm SX multi mode 850 nm ZX single mode 1550 nm CONNECTOR Standard SFP connector A 2 6 Wireless WAN interface WWAN Standard Bands EC25 E LTE FDD B1 B3 B5 B7 B8 B20 TDD B38 B40 B41 WCDMA B1 B5 B8 GSM GPRS EDGE 900 1800 MHz Speed DL UL EC25 E LTE Cat 4 FDD 150Mbps 50Mbps TDD 130Mbps 35Mbps HSPA Cat 24 6 42Mbps 5 76Mbps EDGE 236Kbps CONNECTOR Two RF SMA female connectors Optional...

Page 41: ...rmination config urable through software SPEED From 300 to 115200 bps CONNECTOR RJ 45 female on the device connectors panel optional A 2 10 Power Supply Specifications NOMINAL 110 240 V AC ABSOLUTE MAXIMUM 85 264 V AC FREQUENCY 50 60 Hz MAXIMUM POWER 10 W CONNECTOR Terminal Block 2 Poles 5 08 mm pitch A 2 11 Dimensions and weight TYPE Plastic ruggedized casing with optional DIN rail mount LENGTH x...

Page 42: ...s Technology LTE Bands Frequencies Conducted Transmit Power Band 1 Tx 1920 1980 MHz Rx 2110 2170 MHz 23 dBm 2 dB Band 3 Tx 1710 1785 MHz Rx 1805 1880 MHz 23 dBm 2 dB Band 7 Tx 2500 2570 MHz Rx 2620 2690 MHz 23 dBm 2 dB Band 20 Tx 832 862 MHz Rx 791 821 MHz 23 dBm 1 dB Technology UMTS WCDMA HSDPA HSUPA HSPA DC HSPA Bands Frequencies Conducted Transmit Power Band 1 Tx 1920 1980 MHz Rx 2110 2170 MHz ...

Reviews: