background image

A.3.4

220V Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Appendix B

Regulatory compliance and safety information . . . . . . . . . . . . . . . . .

15

B.1

Recycling and the Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

B.2

Translated Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

B.3

Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

B.3.1

FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

B.3.2

IC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

Table of Contents

Teldat S.A.

ii

MTC+

Summary of Contents for MTC+

Page 1: ...MTC Installation Manual Copyright Teldat Dm689 I Version 2 1 8 2018 Teldat S A Teldat S A Manual MTC 1...

Page 2: ...e Teldat S A offers no warranty whatsoever for information contained in this manual Teldat S A is not liable for any direct indirect collateral consequential or any other damage connected to the deliv...

Page 3: ...Connection 5 3 1 1 Single Management Connection Design 6 3 1 2 Cascade Management Connection Design 7 3 2 Power Connection 7 3 2 1 Normal Power Connection Design 7 3 2 2 Connecting the Management rout...

Page 4: ...ndix B Regulatory compliance and safety information 15 B 1 Recycling and the Environment 15 B 2 Translated Safety Warnings 16 B 3 Compliance 17 B 3 1 FCC Statement 17 B 3 2 IC Statement 17 Table of Co...

Page 5: ...power supply When the fuse needs to be substituted you MUST physically disconnect the device from the main electricity supply and from all other devices and or equipment Only qualified personnel shou...

Page 6: ...ure or maintain net works This guide assumes that the installer is familiar with network electronics and technologies 1 4 What is in this manual This installation guide contains the following informat...

Page 7: ...ftware or hard ware of this product modifying the specifications of this manual without prior notice The images showing the front and back panels of the device are for information purposes only Some s...

Page 8: ...indicates the state of the controlled power supply base if the light is on the controlled power is receiving power from the main electricity supply Consecutive ID herinafter ID This is the ID for the...

Page 9: ...upply Connector Switch on the external device To Disconnect Disconnect the data cable from the MTC Switch off and then disconnect the external device from the Controlled Power Supply Connector Disconn...

Page 10: ...n Troubleshooting 3 1 1 Single Management Connection Design Under this management connection the power supply of a single external device can be controlled through the MTC The following images show th...

Page 11: ...uses a flat RJ45 connector while the input management interface uses an RJ11 connector Fig 4 Cascade Management Connection Note If one MTC does not receive power from the input power supply connector...

Page 12: ...outer managing the MTC If you use this please bear in mind that If you run the on command the router is unavailable until you press the MTC Reset Button On running reset the router is temporally unava...

Page 13: ...quivalent to an OFF command which after 10 seconds is followed by an ON scan Checks that all the MTC registered are still connected status Display the status ON OFF temperature Get current temperature...

Page 14: ...ts defaults probe Configure a probe that will be testing if the MTC has power exit Exit to parent menu Syntax probe id MTC id period probe period track track period Track is optional this enables a pe...

Page 15: ...ion cable for all MTC Check the main power connectors for all MTC Press Reset Button for all MTC You do not receive responses when sending command option all Run list and check that the MTC shown are...

Page 16: ...put Check you don t have two MTC with the same ID Check the management interface connec tions input output Check the main power connectors for all MTC Press the Reset Button for all MTC Warning Do not...

Page 17: ...2 3 4 5 6 7 8 Rx output GND GND Tx Output A 3 Technical Specifications Two models are sold depending on the power supply a 110V model and a 220V model A 3 1 Hardware Architecture PROCESSOR MC9RS08KB12...

Page 18: ...should never be replaced Contact Technical Support should it need substituting A 3 4 220V Model Power Supply Connector C14 male Power Supply Voltage 200 240V AC Input Frequency 47 63Hz Maximum Input...

Page 19: ...s and any additional steps established by law All the packing materials i e the cardboard box plastic and any other packaging together with the pieces making up an MTC must be recycled complying with...

Page 20: ...B 2 Translated Safety Warnings MTC MTC 012 3 3 14 0 12 5 67 8 4 52 8 5 89 2 1 3 00 5 67 8 5 8 5 8 3 MTC 2 1 1 MTC Regulatory compliance and safety information Teldat S A 16 MTC...

Page 21: ...ce may not cause harmful interference and 2 this device must accept any interference received including in terference that may cause undesired operation B 3 2 IC Statement B 3 2 1 CAN ICES 3 B NMB 3 B...