1.2.2 If the Ethernet cable is not POE
To Connect
To Disconnect
Check that the power supply is not connected to the
device.
Disconnect the power supply from the device.
Check that the power supply is not connected to the main
electricity supply.
Disconnect the power supply from the main electricity
supply.
Connect the power supply to the main electricity supply.
Connect the power supply to the device.
1.2.3 Connecting the Power Source
1.2.3.1 With External Power Supply
Fig. 4: Connecting the power source
The Teldat-3Ge can be powered by an external AC/DC power source through the Ethernet cable if it complies with
the POE 802.3af standard.
To connect the power supply to the device, please follow the steps set forth in
If the Ethernet cable is POE
on page 3
above.
Warning
All interconnected communication devices should be plugged to THE SAME GROUNDED
POWER OUTLET, which should, at the same time, be of good quality (lower than 10 ohms).
Whether the workplace is provided with an uninterrupted power supply system (UPS), regulated
supply, or it is independent from the rest (such as lighting, etc.), it is highly recommended that
all data devices should be connected to the same power source. This will avoid operating and
premature aging problems of drivers and other components.
1 Installing the Router
Teldat S.A.
4
Teldat-3Ge Installation Manual