Teldat 3ge Installation Manual Download Page 8

1.2.2 If the Ethernet cable is not POE

To Connect

To Disconnect

Check that the power supply is not connected to the
device.

Disconnect the power supply from the device.

Check that the power supply is not connected to the main
electricity supply.

Disconnect the power supply from the main electricity
supply.

Connect the power supply to the main electricity supply.

Connect the power supply to the device.

1.2.3 Connecting the Power Source

1.2.3.1 With External Power Supply

Fig. 4: Connecting the power source

The Teldat-3Ge can be powered by an external AC/DC power source through the Ethernet cable if it complies with
the POE 802.3af standard.

To connect the power supply to the device, please follow the steps set forth in

If the Ethernet cable is POE

on page 3

above.

Warning

All interconnected communication devices should be plugged to THE SAME GROUNDED
POWER OUTLET, which should, at the same time, be of good quality (lower than 10 ohms).

Whether the workplace is provided with an uninterrupted power supply system (UPS), regulated
supply, or it is independent from the rest (such as lighting, etc.), it is highly recommended that
all data devices should be connected to the same power source. This will avoid operating and
premature aging problems of drivers and other components.

1 Installing the Router

Teldat S.A.

4

Teldat-3Ge Installation Manual

Summary of Contents for 3ge

Page 1: ...Teldat 3Ge Installation Manual Teldat Dm 398 I Copyright Version 9 2 Teldat S A Teldat S A Manual Teldat 3Ge Installation Manual 1...

Page 2: ...offers no warranty whatsoever for information contained in this manual Teldat S A is not liable for any direct indirect collateral consequential or any other damage connected to the deliv ery supply o...

Page 3: ...2 3 Connecting the Power Source 4 1 2 4 Data Connections 5 1 3 Installing the SIM card 8 1 4 Meaning of the LEDS 9 Chapter 2 Appendices 11 2 1 Troubleshooting 11 2 2 Updating the software 11 2 3 Conne...

Page 4: ...Table of Contents Teldat S A ii Teldat 3Ge Installation Manual...

Page 5: ...unique interface with the access router over the corporate Ethernet LAN infrastructure This singular approach avoids deployment of expens ive and bulky ultra low loss coaxial cables needed to link th...

Page 6: ...omestic waste Ask your local town hall for information on how to correctly dispose of them in order to protect the environment against e waste Al ways respect the current laws regarding waste material...

Page 7: ...s etc Avoid knocks and or strong vibrations during operation storage and transport Warning The electric current in power cables telephone lines and communication cables is dangerous To prevent electri...

Page 8: ...through the Ethernet cable if it complies with the POE 802 3af standard To connect the power supply to the device please follow the steps set forth in If the Ethernet cable is POE on page 3 above War...

Page 9: ...3 Figure 6 shows how to connect the POE injector to the Teldat 3Ge Fig 6 Connecting the power with the POE injector 1 2 4 Data Connections The Teldat 3Ge has the following available connectors 1 2 4 1...

Page 10: ...ntenna connector for Wireless WAN without diversity Scenario with diversity Figure 9 shows the location of antenna connectors on routers that use antenna diversity Fig 9 Rear panel Antenna connector f...

Page 11: ...oaxial cable the RF antennas and the SMA connect ors Cable characteristics Mechanical Specifications Storage temperature 40 C to 80 C Operating temperature 40 C to 80 C Minimum curvature of radio 35 m...

Page 12: ...nterfere with the quality of the radio signal We do not recommend that you install antennas in racks containing communication devices computers etc Use an extension cable and place the antenna outside...

Page 13: ...n the network GREEN The module has registered in the network STATUS Device status RED Error in the WWAN module 3G communications are not possible Check that the module is correctly connected Check tha...

Page 14: ...contact the technical service LAN LEFT LED YELLOW There is a physical layer in the Ethernet OFF There is no physical layer Check the Ethernet cable LAN RIGHT LED BLINKING GREEN Data is being received...

Page 15: ...status of the WWAN LED The WWAN LED is blinking in green Check that the SIM card has been inserted correctly Check that the PIN is correct Check that you have configured the correct parameters to reg...

Page 16: ...POE 2 3 2 ANT Connector PIN ANT Internal External RF in out GND 2 3 3 Power Connector PIN ANT Internal External POSITIVE NEGATIVE 2 4 Technical Specifications Hardware Architecture PROCESSORS Coldfire...

Page 17: ...00 mA JACK 5 5 mm INTERNAL PIN 2 5 mm External power source INPUT VOLTAGE 100 240V AC INPUT CURRENT 600 mA INPUT FREQUENCY 50 60 Hz Dimensions and weight TYPE Desktop or attached to wall LENGTH x WIDT...

Page 18: ...2 5 Translated Safety Warnings 0 12 3 0 3 0 3 4 5 5 0 12 3 4 5 0 53 6 0 3 4 7 4 5 0 3 7 5 7 4 0 3 5 7 5 2 Appendices Teldat S A 14 Teldat 3Ge Installation Manual...

Reviews: