39
Installing the Equipment
2.8
Powering Down
The 800 series 1+1 can be turned off using either the management port or the power button.
2.8.1
Management Port
To shut down the unit using the management port, connect to the management interface using SSH,
and enter:
shutdown -hP now
Attention
DO NOT TURN OFF the power to the 800 series gateway unless you have already
performed the previously mentioned shut down procedure. Allow enough time for the
VoIP gateway to shut down before turning the power off (ex. minimum 1 minute). Be
aware that the shutdown procedure of the unit is logged and traceable for support and
warranty purposes.
2.8.2
Power Button
To shut down the unit, press and hold the front power button for one second.
Figure
2.16
Front View LED
Press and hold for 1 second