Product Data 

 

Electrical Data 

 

Transmitter 

Receiver 

Supply Voltage 

10-30 V dc 

Voltage ripple 

15% (within supply range) 

Reverse polarity protected 

Yes 

Short circuit protected 

Yes 

Inductive load protected 

Yes 

Current consumption 

Max. 30 mA 

Max. 8 mA 

Max. output load 

100 mA 

 

Environmental Data 

Temperature, operation 

-20 to +50 ºC 

Light immunity @ 0

O

 incidence 

20.000 lux 

Sealing class 

IP 67 

Approvals 

 

 

 

Available Models 

 

Model 

Output 

Output Mode 

Sensing Range 

Transmitter 

SMT 3010C/CAT2 

10 m 

 

Receiver 

SMR 3010/CAT2 

NPN 

Light operated 

(N.C.) 

SMR 3210/CAT2 

PNP 

Light operated 

(N.C.) 

 

 

General Instructions and Precautions 

 

This light curtain can be used in industrial, commercial and garage doors and gates, as 

described in EN 12453, when it is used as device type E according to clause 5.5.1.  

 

Even though the sensor has a high degree of immunity to ambient light sources, it is 

recommended to avoid direct exposure to sunlight, and interference from flashlights or other 

infrared light sources, such as other photo sensors. 

 

If the front cover of the sensor becomes contaminated, it has to be cleaned with a slightly 

damp cloth. Do not use organic solvents or detergents. If the light curtain is very contaminated, 

the output may go into safe state and de-energize even after the cleaning, due to safety 

reasons.  

 

Ensure that the sensor is mounted, so that it is mechanically stable during operation. 

 

Severe rain and snow may be detected due to the high sensitivity of the light curtain. 

 

 

 

 

Connection

 

 

Wiring Diagrams

 

 

 

 

 

 

 

 

SMT 3000                                                                                        Variable range and test input 

 

 

 

 

 

 

 

 

SMR 3010         Transistor NPN 

SMR 3210         Transistor PNP 

 

Connection Wires

 

 

Brown 

Supply - 

Blue 

Control/Output 

Black 

 

Mounting & Alignment

 

 

Mounting & Alignment 

Mount the transmitter and receiver sensors facing each other. Make sure the distance 

between the sensors does not exceed the specified sensing range of the system. 

Align the sensors by turning, either the transmitter or receiver sensor, horizontally and 

vertically until the output is: 

- Deactivated when no object is present. (Dark operated) 

- Activated when no object is present. (Light operated) 

Fasten the transmitter and receiver sensors securely.  

Avoid acute angles on cable close to sensor. 

 

Adjustments

 

 

Output Logic 

Detection 

Output Mode 

Output status 

Yellow LED 

Object absent  

 

 

 

 

Light operated (N.C.) 

Closed 

On 

Object present 

 

 

 

 

Light operated (N.C.) 

Open 

Off 

 

Transmitter power adjustment 

The transmitting power can be adjusted externally via the wires of the transmitter sensor. 

Adjust using a resistor (e.g. a potentiometer) of 200 ohm to 10k ohm or a voltage source of 1- 

4 V dc connected respectively between control and – supply (ground) wires. Adjustment of the 

transmitter power may be required in applications where objects to be detected are small or 

translucent. Proceed with the following steps: 

Select target object with the smallest dimension and most translucent surface. 

Place target object between transmitter and receiver sensors. If the output is activated, 

adjustment is not required. If the output is not activated proceed to step 3. 

Decrease the transmitter power (by decreasing the resistance) until the output is 

activated. 

Remove target object. Observe the output deactivates. 

Note: If the test input is not to be used (not safety application), it is recommended to connect the 

control wire to + (positive) supply wire. 

 

Indicator LEDs

 

 

Indicator LEDs 

Green LED on transmitter 

Power on indicator 

Yellow LED on receiver 

Indicates closed output 

 

 

Troubleshooting

 

 

Troubleshooting 

Probable Reason 

Corrective Action 

1.

 Symptom: Power indicator (Green LED) on SMT is off. 

No power supply 

Check supply and cable to the SGT 

2.

 Symptom: Output indicator (Yellow LED) on SMR does not correspond to a beam break 

No power supply to SMR 

Check supply and cable to the SMR 

TX is not emitting, green LED off 

Check supply and cable to the SMT 

SMT is disabled 

Enable the SMT 

The sensors are misaligned 

Align the sensors 

3.

 Symptom: Output indicator (Yellow LED) on SMR is flickering 

Severe electrical interference 

Remove SMR and SMT supply cable from high 

voltage cables 

Severe ambient light 

Change position of SMT and SMR 

Cross talk from another light transmitter 

Change position of SMT and SMR 

 

SMR Output Response Time

 

 

SMR Output Response Time (typical) 

Range 

Ton (beam break) 

Toff (beam make) 

2 m 

14 ms 

10 ms 

4 m 

12 ms 

11 ms 

6 m 

11 ms 

15 ms 

8 m 

8 ms 

29 ms 

10 m 

8 ms 

34 ms 

 

SMT Test Input

 

 

SMT Test Input  

If the sensor is used as a safety device in accordance with EN12978, the function of the 

sensor pair has to be tested periodically, at the latest at one of the end positions of the 

door leaf. (EN12978:2003+A1:2009: 4.4.3). 

During the test the transmitter is disabled by connecting the control wire to – supply 

(ground). The control system has to check that the receiver de-energises the output (NC 

system). The control wire of the transmitter is hereafter disconnected or connected to +, 

and it is checked that the receiver re-energises the output. 

Enable transmitter  Open (off) control switch, a resistor over 10k ohm, or voltage over 4 V dc 

Disable transmitter  Close (on) control switch, a resistor below 200 ohm, or voltage below 0,7 V dc 

Note: If the test input is not to be used (not safety application), it is recommended to connect the 

control wire to + (positive) supply wire. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMT test input reaction time (typical) 

Range 

Ton (beam break) 

Toff (beam make) 

Tr (min.) 

2 m 

14 ms 

10 ms 

20 ms 

4 m 

12 ms 

11 ms 

18 ms 

6 m 

11 ms 

15 ms 

17 ms 

8 m 

8 ms 

29 ms 

14 ms 

10 m 

8 ms 

34 ms 

14 ms 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmitter 

Receiver 

Transmitter 

Receiver 