Operating Basics
Loss of Lock:
Enables or disables the mainframe GPI alarm when the TG700
does not lock to a genlock signal. Use the left (
◄
) or right (
►
) arrow
button to select between
Enable
and
Disable
. Press the
ENTER
button to
implement the selection.
Near Loss of Lock:
Enables or disables the mainframe GPI alarm when the
frequency of the genlock signal and the internal reference shift considerably,
and the TG700 seems to be near loss of lock. Use the left (
◄
) or right (
►
)
arrow button to select between
Enable
and
Disable
. Press the
ENTER
button
to implement the selection.
ALG7 ALARM SELECT Submenu.
Use this menu to select which AGL7 module
alarms are enabled or disabled. Use the up (
▲
) or down (
▼
) arrow button to
scroll through the menu items. The following
fi
gure shows the AGL7 ALARM
SELECT submenu.
The AGL7 ALARM SELECT submenu contains the following selections:
No Signal:
Enables or disables the AGL7 module alarm when a genlock
signal is not connected. Use the left (
◄
) or right (
►
) arrow button to select
between
Enable
and
Disable
. Press the
ENTER
button to implement the
selection.
Loss of Lock:
Enables or disables the AGL7 module alarm when the TG700
does not lock to a genlock signal. Use the left (
◄
) or right (
►
) arrow
button to select between
Enable
and
Disable
. Press the
ENTER
button to
implement the selection.
Near Loss of Lock:
Enables or disables the AGL7 module alarm when the
frequency of the genlock signal and the internal reference shift considerably,
and the TG700 appears to be near loss of lock. Use the left (
◄
) or right (
►
)
2–40
TG700 TV Signal Generator Platform User Manual