12. Determine which field you are triggering on. If necessary, use the
Zoom button to magnify the colorburst signal.
Field 1 or 4
Field 2 or 3
Sync
13. If the oscilloscope is triggering on field 2, repeatedly push the
SINGLE SEQ button until the colorburst waveform changes to
the correct phase for field 1, and then push the RUN/STOP
button to resume triggering the oscilloscope.