Preface

This document helps customers with data security concerns to sanitize or remove memory devices from the RSA5100B
Series Real-Time Signal Analyzers.

These products have data storage (memory) devices and data output devices (USB ports). These instructions tell how to
clear or sanitize the memory devices and disable the data output devices. The instructions also tell how to declassify an
instrument that is not functioning.

Reference

The procedures in this document are written to meet the requirements speci

fi

ed in:

NISPOM, DoD 5220.22–M, Chapter 8

ISFO Process Manual for Certi

fi

cation & Accreditation of Classi

fi

ed Systems under NISPOM

Products

The following Tektronix products are covered by this document:

RSA5103B

RSA5106B

RSA5115B

RSA5126B

Terms

The following terms may be used in this document:

Clear.

This removes data on media/memory before reusing it in a secured area. All reusable memory is cleared to

deny access to previously stored information by standard means of access.

Erase.

This is equivalent to clear.

Instrument Declassi

fi

cation.

A term that refers to procedures that must be undertaken before an instrument is

removed from a secure environment. Declassi

fi

cation procedures include memory sanitization and memory removal,

and sometimes both.

RSA5100B Series Declassi

fi

cation and Security Instructions

iii

Summary of Contents for RSA5103B

Page 1: ...RSA5100B Series Real Time Signal Analyzers Declassification and Security ZZZ Instructions xx www tektronix com P077090200 077 0902 00...

Page 2: ...and pending Information in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tek...

Page 3: ...Clear and Sanitize Procedures 1 Memory Devices 1 Media and Data Export Devices 7 Troubleshooting 11 How to Clear or Sanitize a Non Functional Instrument 11 Change Log 12 RSA5100B Series Declassificati...

Page 4: ...Table of Contents ii RSA5100B Series Declassification and Security Instructions...

Page 5: ...ess Manual for Certification Accreditation of Classified Systems under NISPOM Products The following Tektronix products are covered by this document RSA5103B RSA5106B RSA5115B RSA5126B Terms The follo...

Page 6: ...nstrument Instructions are available in the product Service Manual Sanitize This eradicates the data from media memory so that the data cannot be recovered by other means or technology This is typical...

Page 7: ...ers User settings Describes the type of information stored in the device Refers to instrument settings that can be changed by the user Both Describes the type of information stored in the device It me...

Page 8: ...t 20 seconds SRAM 2 MB Power PC system memory None No Indirect Firmware operations Digital Interface board No Remove power from the instrument for at least 20 seconds Remove power from the instrument...

Page 9: ...Reinstall Microsoft Windows using the OS Restore procedure in the Quick Start User Manual Reinstall the instrument software using the supplied recovery disk See Clearing Hard Disk Drives Remove the h...

Page 10: ...y Not applicable does not contain user data or settings Sanitizing would disable instrument functionality Flash 1 Mb Unused for future software enhancements None None None RFI board No Not applicable...

Page 11: ...lose the RSA5100B application and erase the free space on the hard disk using commercial software Fixed Hard Drive Removal Procedure The following procedure applies to instruments with Option 59 Fixed...

Page 12: ...nts with Option 56 Removable Hard Disk Drive installed For detailed information on removing parts from the instrument see the RSA5100B Series Real Time Signal Analyzers Service Manual Tektronix part n...

Page 13: ...nect from Network cable GPIB connector Supports remote control and data transfer Directly System resources Rear panel N A Disabling the USB Ports Use the following procedure to disable the front and r...

Page 14: ...g 1 Reboot the instrument and press the Delete key to access the BIOS settings screen 2 Select Set Password 3 Choose a BIOS password 4 Confirm the new BIOS password 5 Save the BIOS settings and exit E...

Page 15: ...nt be sure to perform this procedure exactly as stated A misconfigured BIOS can make the instrument unusable and require that it be returned to Tektronix for servicing 1 Reboot instrument and press th...

Page 16: ...Clear and Sanitize Procedures 10 RSA5100B Series Declassification and Security Instructions...

Page 17: ...strument Hard Disk Drives Remove the internal hard disk Option 59 or removable hard disk Option 56 using the procedures in this document External Memory Devices Remove any USB flash drives or external...