background image

RSA5BUP (Options 65, 66, and 6566)

RSA5UP (Option 5566)

RSA5100A and RSA5100B Series Real-Time Signal Analyzers

Digital I and Q Outputs and Zero Span Output Upgrades

ZZZ

Instructions

xx

www.tektronix.com

*P075106100*

075-1061-00

Summary of Contents for RSA5103A

Page 1: ...ptions 65 66 and 6566 RSA5UP Option 5566 RSA5100A and RSA5100B Series Real Time Signal Analyzers Digital I and Q Outputs and Zero Span Output Upgrades ZZZ Instructions xx www tektronix com P075106100 075 1061 00 ...

Page 2: ...ed by national copyright laws and international treaty provisions Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc ...

Page 3: ...able of rendering first aid and resuscitation is present Disconnect Power To avoid electric shock switch off the instrument power then disconnect the power cord from the mains power Use Care When Servicing With Power On Dangerous voltages or currents may exist in this product Disconnect power remove battery if applicable and disconnect test leads before removing protective panels soldering or repl...

Page 4: ...nd Q Outputs and Zero Span Output RSA5100A Series Option 5566 Digital I and Q Outputs and Zero Span Output Products RSA5103B All serial numbers RSA5106B All serial numbers RSA5115B All serial numbers RSA5126B All serial numbers RSA5103A All serial numbers RSA5106A All serial numbers RSA5115A All serial numbers RSA5126A All serial numbers 2 RSA5100A B Series Digital I Q and Zero Span Upgrades ...

Page 5: ... W SHIELD NOTE These cables are not needed to install the Option They are supplied for external connections to the I and Q Output connectors 1 174 5213 XX CABLE ASSY RIBBON STATIC GROUND 1X2 SAFETY CONTROLLED 1 174 6418 XX CABLE COAX BNC ST TO SMB RA 1 200 5317 XX COVER REAR PANEL OPTION I AND Q ZERO SPAN 4 211 0450 XX SCREW MACHINE 2 5MM X 0 45 X 6MM PNH STEEL ZINC PLATED T8 TORX DRIVE 8 211 1050...

Page 6: ...r 6 5 32 hex wrench NOTE Only needed for early models of the RSA5100A Series instruments Hex wrench to remove Allen head screws at front of top cover These instructions are for qualified service personnel who are familiar with servicing the product If you need further details for disassembling or reassembling the product refer to the product s Service Manual Remove cosmetic covers and shield NOTE ...

Page 7: ...top cover next to the folding handles NOTE Early models of the RSA5100A Series instruments used four 5 32 Allen socket cap screws in place of the T15 Torx head screws 5 Remove the top and bottom covers Remove the top cover by pulling straight back about 1 inch Then pull out on the sides of the top cover outward flexing them slightly to clear the instrument chassis and pull it away from the instrum...

Page 8: ...Installation instructions Figure 1 Remove covers 6 RSA5100A B Series Digital I Q and Zero Span Upgrades ...

Page 9: ...nel cover using four T8 Torx head screws provided in the kit Tighten the screws using a torque driver set to 5 5 in lb Install the Ground cable onto the spade connector on the rear panel cover Install the Zero Span Output BNC cable to the rear panel cover Use the BNC washer and 5 8 nut that is provided with the BNC connector Figure 2 Installing cables RSA5100A B Series Digital I Q and Zero Span Up...

Page 10: ...eight T15 Torx head screws Discard the blank panel 2 Install the new rear panel cover with attached cabling on the rear panel chassis using eight T15 Torx head screws Torque these screws to 10 0 in lb See Figure 3 Figure 3 Installing the rear panel cover on the rear panel of the chassis 8 RSA5100A B Series Digital I Q and Zero Span Upgrades ...

Page 11: ...AUTION Be careful not to bend the pins on the Interface Board when installing the option board Figure 4 Installing the option board 2 Connect the cables from the rear panel cover to the Option board See Figure 5 Connect the 2 wire ground cable Connect the I and Q output cables Connect the Zero Span output cable RSA5100A B Series Digital I Q and Zero Span Upgrades 9 ...

Page 12: ... top cover over the top of the instrument and slide it toward the front panel Make sure that the top cover wraps around the flanges on the rear panel on all three sides 5 Reinstall the four T20 Torx head screws two on each side near the front edge of the top cover next to the folding handles that secure the top cover to the instrument Torque these screws to 8 0 in lb 6 Rotate the instrument so the...

Page 13: ...n RSA5100A Series instrument the software most likely requires updating to recognize the new feature This should be done before installing the new option key See the procedure Verify instrument software version To activate your new option you must enter a new option key 1 Power on the instrument NOTE When the application launches it will display an error message indicating that the current option ...

Page 14: ...ektronix Real Time Analyzer 7 Verify the new option is listed Attach labels Please attach all labels provided in this kit on the instrument s rear panel Attach the option key label Place the new option key label over the existing label on the rear panel Attach the product option label Place the new product label over the existing label on the rear panel 12 RSA5100A B Series Digital I Q and Zero Sp...

Page 15: ...rify instrument software version Tektronix recommends to update to the latest available application software for your instrument 1 Select Help About to check the software version 2 Use your Web browser to go to www tektronix com software 3 Search for your instrument s model number and follow the link to the software 4 If the installed software is older than that available download the software 5 F...