background image

Warranted characteristics

When the instrument is installed according to the instructions in this document, the rackmounted instrument meets all warranted
requirements listed in the instrument specification. Instruments mounted using methods other than those described in these
instructions might not meet their warranted requirements.

For tables of the warranted characteristics, see Specifications in the specification and performance verification manual that
applies to your instrument model.

CAUTION. The instrument might be damaged due to overheating. When installing multiple instruments in an instrument rack, the
ambient temperature may go up. You assume the responsibility to provide adequate cooling to meet the ambient temperature
requirements listed in the specifications.

The ambient temperature inside the instrument rack will vary depending on the location of the instrument within the instrument
rack. Tektronix recommends that you measure the ambient temperature in the desired rack location before you install the
instrument to ensure the operating temperature does not exceed the rated ambient temperature limit. If necessary, refer to the
Environmental Specifications in your product documentation for the operating temperature limits.

Clearance requirements

The rack in which the individual instrument is mounted must provide the following clearance requirements:

At least 218 mm (8.6 in) of vertical space

A minimum width of 488 mm (19.2 in) between the left- and right-front rails in the rack. If possible, consider allowing at least
50.8 mm (2.0 in) on the right side and rear of the instrument for adequate airflow.

A minimum inside depth of at least 384 mm (15.1 in) depth (from rack mounting ear to back of instrument)

Airflow enters from the back of the instrument and exits on the right of the instrument when viewed from the front.

CAUTION. Adhering to these requirements mounts the rack-adapted instrument with enough clearance for air circulation and
accommodation of the power cord and mounting hardware. Failure to provide these clearances can result in overheating and can
cause the instrument to operate improperly or fail.

 

Kit description

RM5 Rackmount Kit 

3

Summary of Contents for RM5

Page 1: ...52302 071 3523 02 Warning The servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless you are qualified to do so Refer to all safety summaries prior to performing service ...

Page 2: ...sued and pending Information in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc Contacting Tektronix Tektronix Inc 14150 SW Karl Braun Drive P O Box 500 Beaverton OR 97077 USA For product information sales service and technical support In North America call 1 800 8...

Page 3: ...y iii Kit description Products 1 Minimum tool and equipment list 1 Kit parts list 1 Warranted characteristics 3 Clearance requirements 3 RM5 Installation instructions Assemble the instrument on the rack platform 5 Dimensions Front panel 11 Rear panel 13 RM5 Rackmount Kit i ...

Page 4: ...Table of Contents ii RM5 Rackmount Kit ...

Page 5: ...f this product unless another person capable of rendering first aid and resuscitation is present Disconnect power To avoid electric shock switch off the product power and disconnect the power cord from the mains power before removing any covers or panels or opening the case for servicing Use care when servicing with power on Dangerous voltages or currents may exist in this product Disconnect power...

Page 6: ...Important safety information iv RM5 Rackmount Kit ...

Page 7: ...lists the parts for the kit not all of the parts will be needed for your instrument setup Item Quantity Part number Description 1 each 071 3523 xx RM5 RACK MOUNT KIT INSTRUCTIONS 1 each 644 1088 xx RACKMOUNT KIT CONSISTING OF THE FOLLOWING ITEMS 1 1 407 5871 00 BRACKET ASSEMBLY LEFT SAFETY CONTROLLED 2 1 407 5872 00 BRACKET ASSEMBLY RIGHT RACK KIT SAFETY CONTROLLED 3 4 2 407 5870 00 BRACKET BOTTOM...

Page 8: ...INC PLATED STEEL 14 210 1548 00 WASHER FLAT 12 OD X 6 4 ID X 1 6THK 14 211 1218 00 SCREW M6 X 16MM OVAL HEAD PHILLIPS 14 211 1219 00 SCREW M5 X 16MM OVAL HEAD PHILLIPS 14 212 0591 00 SCREW MACHINE 10 32X 750 OVAL HEAD POZI 14 213 0199 00 SCREW MACHINE 12 24 X 0 75 OVH STL NP POZ 7 1 351 1095 00 SLIDE ASSY PAIR W STD HARDWARE KIT AND REAR BRACKET SAFETY CONTROLLED The following figure shows an expl...

Page 9: ...ed rack location before you install the instrument to ensure the operating temperature does not exceed the rated ambient temperature limit If necessary refer to the Environmental Specifications in your product documentation for the operating temperature limits Clearance requirements The rack in which the individual instrument is mounted must provide the following clearance requirements At least 21...

Page 10: ...Kit description 4 RM5 Rackmount Kit ...

Page 11: ...product refer to the appropriate product manual Contact your nearest Tektronix Inc Service Center or Tektronix Factory Service for installation assistance Assemble the instrument on the rack platform A 5 Series MSO is shown in the illustrations 1 Remove the handle hubs and grill as shown Save the handle hubs hub screws and grill for future use Figure 2 Prepare the instrument RM5 Rackmount Kit 5 ...

Page 12: ...2 Install the left and right mounting plates Use the M4 screws from item 5 Figure 3 Mounting plate installation RM5 Installation instructions 6 RM5 Rackmount Kit ...

Page 13: ...plates and handle as shown Use the M3 screws from item 5 to assemble the support plates Use the 10 32 flat head screws from item 5 to attach the handles Figure 4 Support plate installation RM5 Installation instructions RM5 Rackmount Kit 7 ...

Page 14: ...4 Install the left side and right side rack mounts as shown Use M4 screws from item 5 to attach the slides Figure 5 Rack mount installation RM5 Installation instructions 8 RM5 Rackmount Kit ...

Page 15: ...e rack slides and using hardware from items 6 and 7 as appropriate for your rack install the rack slides in your equipment rack Figure 6 Installing the rail slides RM5 Installation instructions RM5 Rackmount Kit 9 ...

Page 16: ...n procedure verify that the instrument and the rack cabinet will not tip forward while the instrument is in the extended position Do not leave the instrument extended when finished accessing the instrument 7 Install the power cord Provide access to a power plug or mains disconnect switch for turning the instrument on off 8 Optionally install any cables you need connected to the instrument rear pan...

Page 17: ...Dimensions Front panel Figure 8 5 Series MSO front panel RM5 Rackmount Kit 11 ...

Page 18: ...Figure 9 6 Series MSO front panel Dimensions 12 RM5 Rackmount Kit ...

Page 19: ...Rear panel Figure 10 5 Series MSO and 6 Series MSO rear panel Dimensions RM5 Rackmount Kit 13 ...

Page 20: ...Dimensions 14 RM5 Rackmount Kit ...