Commands Listed in Alphabetical Order
Returns
A string that includes <manufacturer>, <model>, <serial number>, and
<
fi
rmware_version> as de
fi
ned in the following table.
<manufacturer>
<model>
<serial number>
<
fi
rmware_version>
tektronix
PWS4XXX
XXXXXX
X. XX-X. XX
Examples
*IDN?
might return the following response for a PWS4323:
TEKTRONIX , PWS4323 , 000004 , 1.01–1.20
MEASure:CURRent[:DC]? (Query Only)
This command initiates and executes a new current measurement, and returns the
measured output current of the power supply.
Group
Measurement
Syntax
MEASure:CURRent[:DC]?
Related Commands
Returns
<NR2>
is the measured output current in amperes.
Examples
MEAS:CURR?
might return 0.09998, which would be the measured current on the
output of the power supply in amperes.
MEASure:VOLTage[:DC]? (Query Only)
This command initiates and executes a new voltage measurement, and returns the
measured output voltage of the power supply.
Group
Measurement
Syntax
MEASure:VOLTage[:DC]?
Related Commands
2-18
PWS4205, PWS4305, PWS4323, PWS4602, and PWS4721 Power Supply Programmer Manual
Summary of Contents for PWS4205