Once the load tries to draw more than 0.3 amperes, however, the
supply holds the current to 0.3 amperes (unless OCP is on) and
allows the voltage level to vary accordingly. The power supply then
indicates C.C. on the display.
Setting Voltage and Current Steps
The CURRENT and VOLTS
(step up) and
(step down) arrow
keys allow you to make minor adjustments to the current and voltage
settings.
The STEP SET function determines the amount that the arrow keys
increment or decrement the setting when you press them.
Press STEP SET
→
VOLTS SET
→
(number)
→
(return
) to set
the amount of each voltage step increment and decrement.
Press STEP SET
→
CURRENT SET
→
(number)
→
(return
) to
set the amount of each current step increment and decrement.
NOTE
. The power supplies permit voltage steps up to 2.000 V and
current steps up to 0.200 A.
Example: Set voltage steps to 0.5 V and current steps to 0.1 A.
1. Set voltage steps to 0.5 V:
STEP SET
→
VOLTS SET
→
.5
→
(return
)
2. Set current steps to 0.1 A:
STEP SET
→
CURRENT SET
→
.1
→
(return
)
Press VOLTS
to increase (and press VOLTS
to decrease) the
voltage limit by steps of 0.5 V.
Press CURRENT
to increase (and press CURRENT
to
decrease) the current limit by steps of 0.1 A.
Press and hold the arrow key to increase the selection speed.
Summary of Contents for PS2520
Page 1: ...User Manual PS2520 PS2520G PS2521 PS2521G Programmable Power Supplies 070 9196 01...
Page 4: ......
Page 14: ...Preface viii PS2520 PS2520G PS2521 PS2521G User Manual...
Page 40: ...Operating Basics 26 PS2520 PS2520G PS2521 PS2521G User Manual...
Page 50: ...Appendix B Maintenance 36 PS2520 PS2520G PS2521 PS2521G User Manual...
Page 56: ...Index 42 PS2520 PS2520G PS2521 PS2521G User Manual...