Specifications

P6101B Instructions

7

Table 3: Certifications and compliances (Cont.)

Installation Category
Descriptions

Terminals on this product may have different installation category
designations. The installation categories are:

CAT III

Distribution-level mains (usually permanently 
connected). Equipment at this level is typically 
in a fixed industrial location

CAT II

Local-level mains (wall sockets). Equipment at
this level includes appliances, portable tools, 
and similar products. Equipment is usually
cord-connected

CAT I

Secondary (signal level) or battery operated 
circuits of electronic equipment

Pollution Degree 2

Do not operate in environments where conductive pollutants may
be present.

600V

500V

400V

300V

200V

100V

0

10MHz

15MHz

1MHz

Figure 1: Maximum Working Voltage Derating Curve (V

RMS

)

Summary of Contents for P6101B

Page 1: ...Instructions P6101B 15 MHz 1X Passive Probe 070 7819 07...

Page 2: ...tents issued and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved Printed in the U S A Tektronix Inc P O...

Page 3: ...nal is at ground potential Do not connect the common terminal to elevated voltages Do Not Operate With Suspected Failures If you suspect there is damage to this product have it inspected by qualified...

Page 4: ...e attempting to connect a probe tip accessory BNC to probe tip adapter To install the adapter push the wide end firmly into a BNC connector Then insert the probe tip firmly into the adapter Retractabl...

Page 5: ...from electric shock WARNING To avoid electric shock when using the probe keep fingers behind the guard on the probe body Ground Lead Use the alligator clip to attach the probe to a ground reference Lo...

Page 6: ...than accessories only the probe tip is replaceable Replacement probe tips are available as optional accessories Refer to the replaceable parts list at the end of this manual for more information To r...

Page 7: ...f at least 20 minutes and be in an environment that does not exceed the limits described in Table 2 Table 1 Electrical Characteristics Attenuation system 1X 1 05 at DC Input Resistance system 1 M 1 0...

Page 8: ...ated to the following specification as listed in the Official Journal of the European Communities Low Voltage Directive 73 23 EEC as amended by 93 68 EEC EN 61010 1 A2 1995 Safety requirements for ele...

Page 9: ...pment at this level is typically in a fixed industrial location CAT II Local level mains wall sockets Equipment at this level includes appliances portable tools and similar products Equipment is usual...

Page 10: ...8 P6101B Instructions Replaceable Parts Optional Accessories Standard Accessories 1 2 3 4 5 6 7 8 Figure 2 P6101B replaceable parts...

Page 11: ...R ASSY 3 196 3120 01 1 LEAD ELECTRICAL PROBE GND 6 0 L 80009 196 3120 01 4 016 0633 00 1 MARKER SET CA 2 EA VARIOUS COLORS 80009 016 0633 00 5 013 0277 00 1 ADAPTER CONN BNC TO MINIATURE PROBE TIP 249...

Page 12: ...Address City State Zip Code 24931 BERG ELECTRONICS INC BERG ELECTRONICS RF COAXIAL DIV 2100 EARLYWOOD DR PO BOX 547 FRANKLIN IN 46131 80009 TEKTRONIX INC 14150 SW KARL BRAUN DR PO BOX 500 BEAVERTON OR...

Page 13: ...tions This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care Tektronix shall not be obligated to furnish service under this...

Reviews: