PA-378 Rev. C / October 2013 

 

Safety precautions 

The following safety precautions should be observed before using this product and any associated instrumentation. Although 
some instruments and accessories would normally be used with nonhazardous voltages, there are situations where hazardous 
conditions may be present. 

This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions 
required to avoid possible injury. Read and follow all installation, operation, and maintenance information carefully before using 
the product. Refer to the user documentation for complete product specifications. 

If the product is used in a manner not specified, the protection provided by the product warranty may be impaired. 

 

The types of product users are: 

Responsible body

 is the individual or group responsible for the use and maintenance of equipment, for ensuring that the 

equipment is operated within its specifications and operating limits, and for ensuring that operators are adequately trained. 

Operators

 use the product for its intended function. They must be trained in electrical safety procedures and proper use of the 

instrument. They must be protected from electric shock and contact with hazardous live circuits. 

Maintenance personnel

 perform routine procedures on the product to keep it operating properly, for example, setting the line 

voltage or replacing consumable materials. Maintenance procedures are described in the user documentation. The procedures 
explicitly state if the operator may perform them. Otherwise, they should be performed only by service personnel. 

Service personnel

 are trained to work on live circuits, perform safe installations, and repair products. Only properly trained 

service personnel may perform installation and service procedures. 

 

Keithley Instruments products are designed for use with electrical signals that are measurement, control, and data I/O 
connections, with low transient overvoltages, and must not be directly connected to mains voltage or to voltage sources with high 
transient overvoltages. Measurement Category II (as referenced in IEC 60664) connections require protection for high transient 
overvoltages often associated with local AC mains connections. Certain Keithley measuring instruments may be connected to 
mains. These instruments will be marked as category II or higher. 

Unless explicitly allowed in the specifications, operating manual, and instrument labels, do not connect any instrument to mains. 

Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test 
fixtures. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 
30 V RMS, 42.4 V peak, or 60 VDC are present. A good safety practice is to expect that hazardous voltage is present in any 
unknown circuit before measuring. 

Operators of this product must be protected from electric shock at all times. The responsible body must ensure that operators 
are prevented access and/or insulated from every connection point. In some cases, connections must be exposed to potential 
human contact. Product operators in these circumstances must be trained to protect themselves from the risk of electric shock. If 
the circuit is capable of operating at or above 1000 V, no conductive part of the circuit may be exposed. 

 

Do not connect switching cards directly to unlimited power circuits. They are intended to be used with impedance-limited 
sources. NEVER connect switching cards directly to AC mains. When connecting sources to switching cards, install protective 
devices to limit fault current and voltage to the card. 

Before operating an instrument, ensure that the line cord is connected to a properly-grounded power receptacle. Inspect the 
connecting cables, test leads, and jumpers for possible wear, cracks, or breaks before each use. 

When installing equipment where access to the main power cord is restricted, such as rack mounting, a separate main input 
power disconnect device must be provided in close proximity to the equipment and within easy reach of the operator. 

For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit under 
test. ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting 
cables or jumpers, installing or removing switching cards, or making internal changes, such as installing or removing jumpers. 

 

Do not touch any object that could provide a current path to the common side of the circuit under test or power line (earth) 
ground. Always make measurements with dry hands while standing on a dry, insulated surface capable of withstanding the 
voltage being measured. 

For safety, instruments and accessories must be used in accordance with the operating instructions. If the instruments or 
accessories are used in a manner not specified in the operating instructions, the protection provided by the equipment may be 
impaired. 

Summary of Contents for KEITHLEY 8606

Page 1: ...nd possible instrument damage do not use the Model 8606 probe tips to measure voltages that exceed 30 VRMS 42 Vpeak Do not exceed the maximum signal levels of the accessory or the attached instrument as defined in the specifications and operating information Inspect the probe tips lead insulation and insulating sheaths for wear cracks or breaks before each use To prevent voltages from being expose...

Page 2: ... High Performance Probe Tip Kit 2 PA 378 Rev C October 2013 Characteristics Spade lugs Voltage 42 V Current 10 A Spring hook test probes alligator clips and banana adapters Voltage 1000 V Category II Current 3 A ...

Page 3: ... specifications operating manual and instrument labels do not connect any instrument to mains Exercise extreme caution when a shock hazard is present Lethal voltage may be present on cable connector jacks or test fixtures The American National Standards Institute ANSI states that a shock hazard exists when voltage levels greater than 30 V RMS 42 4 V peak or 60 VDC are present A good safety practic...

Page 4: ...angers that might result in personal injury or death Always read the associated information very carefully before performing the indicated procedure The CAUTION heading in the user documentation explains hazards that could damage the instrument Such damage may invalidate the warranty Instrumentation and accessories shall not be connected to humans Before performing any maintenance disconnect the l...

Reviews: