PA-702 Rev. B / September 2016 

 

The 

CAUTION

 heading in the user documentation explains hazards that could damage the instrument. Such damage may 

invalidate the warranty. 

Instrumentation and accessories shall not be connected to humans. 

Before performing any maintenance, disconnect the line cord and all test cables. 

To maintain protection from electric shock and fire, replacement components in mains circuits — including the power 
transformer, test leads, and input jacks — must be purchased from Keithley Instruments. Standard fuses with applicable national 
safety approvals may be used if the rating and type are the same. The detachable mains power cord provided with the 
instrument may only be replaced with a similarly rated power cord. Other components that are not safety-related may be 
purchased from other suppliers as long as they are equivalent to the original component (note that selected parts should be 
purchased only through Keithley Instruments to maintain accuracy and functionality of the product). If you are unsure about the 
applicability of a replacement component, call a Keithley Instruments office for information. 

Unless otherwise noted in product-specific literature, Keithley instruments are designed to operate indoors only, in the following 
environment: Altitude at or below 2,000 m (6,562 ft); temperature 0 °C to 50 °C (32 °F to 122 °F) ; and pollution degree 1 or 2. 

To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do not apply 
cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with 
no case or chassis (e.g., a data acquisition board for installation into a computer) should never require cleaning if handled 
according to instructions. If the board becomes contaminated and operation is affected, the board should be returned to the 
factory for proper cleaning/servicing. 

Safety precaution revision as of March 2016. 

 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for Keithley 4200-TRX Series

Page 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective...

Page 2: ...necting the 4200A SCS Parameter Analyzer to the 4200A CVIV Multi Switch 4200 TRX 0 75 Connecting to the FORCE or SENSE terminal on the 4200 SCS or 4200A SCS ground unit One end connects to the FORCE connector on the 4200 PA installed in the system The other end connects to the test fixture or probe station holding the DUT The 4200 TRX is available in different lengths The in the model number repre...

Page 3: ...ner shield to outer shield 250 VDC Center conductor to outer shield 250 VDC Center conductor to inner shield 100 V Insulation resistance 1 x 1013 Ω minimum Operating environment 0 ºC to 50 ºC up to 70 percent relative humidity at 35 ºC Center conductor resistance 0 1 Ω per foot Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 4: ...or higher Unless explicitly allowed in the specifications operating manual and instrument labels do not connect any instrument to mains Exercise extreme caution when a shock hazard is present Lethal voltage may be present on cable connector jacks or test fixtures The American National Standards Institute ANSI states that a shock hazard exists when voltage levels greater than 30 V RMS 42 4 V peak o...

Page 5: ...rough Keithley Instruments to maintain accuracy and functionality of the product If you are unsure about the applicability of a replacement component call a Keithley Instruments office for information Unless otherwise noted in product specific literature Keithley instruments are designed to operate indoors only in the following environment Altitude at or below 2 000 m 6 562 ft temperature 0 C to 5...

Page 6: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: