Series 2268 850 Watt DC Power Supplies Reference Manual
Local Operation
2268S-901-01 Rev. A / January 2015
59
USER SETTING MEMORY LOCATIONS
There are three user setting memory locations available for storing frequently used
configurations. These user setting memory locations help to facilitate multiple users of a
Series 2268 power supply who have different setups or when multiple loads are used that
have different requirements. The table that follows lists the values that are stored in each user
setting memory location.
Voltage Setpoint
Current Setpoint
Voltage Output Protection
Current Output Protection
Over Voltage Protection (OVP)
Over Temperature Protection (OTP)
Autostart OUTPUT ENABLE Main
Autostart OUTPUT ENABLE Aux
Foldback Mode
Foldback Delay
Shutdown Logic
Voltage Analog Programming (VAP) Mode
Voltage Analog Programming (VAP) Level
Current Analog Programming (CAP) Mode
Current Analog Programming (CAP) Level
Current Sharing Mode
Alarm Latches
Front Panel Timeout
Saving User Setting Memory Locations
To save user setting memory locations:
1.
Turn the 9-position mode control to the SAV position.
is displayed on the output voltage display with a number indicating a preset
position which is displayed on the output current display.
2.
Turn the rotary Adjust/Enter control to select a preset position from 1 to 3.
3.
Press the rotary Adjust/Enter control.
done is displayed on the output voltage display.
4.
The setting has now been saved to the selected user setting memory location.
The SCPI command (s) for these instructions are:
*SAV <setting_location>
or
[:]SYSTem[<channel>]:SAVE <setting_location>