Safety

Do not touch any object that could provide a current path to the common side of the 

circuit under test or power line (earth) ground. Always make measurements with dry 

hands while standing on a dry, insulated surface capable of withstanding the voltage 

being measured.

When fuses are used in a product, replace with the same type and rating for 

continued protection against fire hazard.

For safety, instruments and accessories must be used in accordance with the 

operating instructions. If the instruments or accessories are used in a manner not 

specified in the operating instructions, the protection provided by the equipment may 

be impaired.

Do not exceed the maximum signal levels of the instruments and accessories. 

Maximum signal levels are defined in the specifications and operating information and 

shown on the instrument panels, test fixture panels, and switching cards.

Chassis connections must only be used as shield connections for measuring circuits, 

NOT as protective earth (safety ground) connections.

If you are using a test fixture, keep the lid closed while power is applied to the device 

under test. Safe operation requires the use of a lid interlock.

If a        screw is present, connect it to protective earth (safety ground) using the wire 

recommended in the user documentation.

The        symbol on an instrument means caution, risk of hazard. The user must refer 

to the operating instructions located in the user documentation in all cases where the 

symbol is marked on the instrument.

The        symbol on an instrument means warning, risk of electric shock. Use standard 

safety precautions to avoid personal contact with these voltages.

The       symbol on an instrument shows that the surface may be hot. Avoid personal 

contact to prevent burns.

The     symbol indicates a connection terminal to the equipment frame.

If this       symbol is on a product, it indicates that mercury is present in the display 

lamp. Please note that the lamp must be properly disposed of according to federal, 

state, and local laws.

The 

WARNING 

heading in the user documentation explains hazards that might result 

in personal injury or death. Always read the associated information very carefully 

before performing the indicated procedure.

The 

CAUTION 

heading in the user documentation explains hazards that could 

damage the instrument. Such damage may invalidate the warranty.

The 

CAUTION 

heading with the       symbol in the user documentation explains 

hazards that could result in moderate or minor injury or damage the instrument. 

Always read the associated information very carefully before performing the indicated 

procedure. Damage to the instrument may invalidate the warranty.

Instrumentation and accessories shall not be connected to humans.

Before performing any maintenance, disconnect the line cord and all test cables.

To maintain protection from electric shock and fire, replacement components in mains 

circuits — including the power transformer, test leads, and input jacks — must be 

purchased from Keithley. Standard fuses with applicable national safety approvals 

may be used if the rating and type are the same. The detachable mains power cord 

provided with the instrument may only be replaced with a similarly rated power cord. 

Other components that are not safety-related may be purchased from other suppliers 

as long as they are equivalent to the original component (note that selected parts 

should be purchased only through Keithley to maintain accuracy and functionality of 

the product). If you are unsure about the applicability of a replacement component, 

call a Keithley office for information.

Unless otherwise noted in product-specific literature, Keithley instruments are 

designed to operate indoors only, in the following environment: Altitude at or below 

2,000 m (6,562 ft); temperature 0 °C to 50 °C (32 °F to 122 °F); and pollution degree 

1 or 2.

To clean an instrument, use a cloth dampened with deionized water or mild, 

water-based cleaner. Clean the exterior of the instrument only. Do not apply cleaner 

directly to the instrument or allow liquids to enter or spill on the instrument. Products 

that consist of a circuit board with no case or chassis (e.g., a data acquisition board 

for installation into a computer) should never require cleaning if handled according to 

instructions. If the board becomes contaminated and operation is affected, the board 

should be returned to the factory for proper cleaning/servicing.

Safety precautions as of June 2018.

Summary of Contents for Keithley 2182A

Page 1: ...Model 2182A Nanovoltmeter Quick Start Guide...

Page 2: ...high transient overvoltages often associated with local AC mains connections Certain Keithley measuring instruments may be connected to mains These instruments will be marked as category II or higher...

Page 3: ...read the associated information very carefully before performing the indicated procedure The CAUTION heading in the user documentation explains hazards that could damage the instrument Such damage ma...

Page 4: ...100 V ac 120 V ac 220 V ac 240 V ac 50 Hz 60 Hz and 400 Hz automatically sensed at power up Power consumption 22 VA Operating environment Specified for 0 C to 50 C specified to 80 relative humidity a...

Page 5: ...umentation for the 2182A instrument is available for download on the Keithley web page at tek com en products keithley The 2182A documentation includes Quick Start Guide This document It provides unpa...

Page 6: ...hipping agent immediately 6 There may be a protective film over the display lens which can be removed You receive the 2182A with these accessories and documents Power line cord DeoxIT Contact Cleaner...

Page 7: ...allowed voltage in the system is 300 V dc Cover the device under test DUT to protect the operator from flying debris in the event of a system or DUT failure Make sure any test fixture connected to the...

Page 8: ...tch Connect line power The 2182A operates from a line voltage of 100 V ac 120 V ac 220 V ac or 240 V ac at line frequencies of 45 Hz to 66 Hz or 360 Hz to 440 Hz It automatically senses line frequency...

Page 9: ...instrument by pressing the front panel POWER switch to the on position You must turn on the 2182A and allow it to warm up for at least 2 hours to achieve rated accuracies Power up sequence On power up...

Page 10: ...t or above 42 VPEAK To prevent electric shock that could result in personal injury or death never make or break connections while hazardous voltage is present CAUTION Exceeding the following limits ma...

Page 11: ...You can use this cable to make voltage measurements and temperature measurements that use an external simulated reference junction To make voltage connections clamp the cleaned copper lugs of the cabl...

Page 12: ...in a test circuit The following figure shows typical connections to measure a DUT using a single channel The following figure shows typical connections to make comparison measurements of two devices i...

Page 13: ...hows connections using the internal reference junction The thermocouple wires must be soldered directly to the CHANNEL connector The following figure shows temperature only connections using an ice ba...

Page 14: ...tion Press SHIFT then MX B to choose the mx b function Make a voltage measurement The following test verifies basic operation of the 2182A In this test you use the front panel controls to make a volta...

Page 15: ...e thermocouple type that you are using to measure temperature 6 Select JUNC and select the type of reference measurement To reference measurements to the internal reference junction Select INTRNL To r...

Page 16: ...sconnected Select DCV1 or DCV2 as appropriate Press REL to null offsets Repeat for other channel if needed Connect the source and make the measurement Keep the 2182A and test circuit away from electri...

Page 17: ...Next steps For more information refer to the Keithley Instruments website tek com en products keithley You can find support and additional information about the instrument in the Model 2182A Nanovolt...

Page 18: ...d by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TE...

Reviews: