background image

HDST1 HD-SDI Stress Test Module User Manual

3-7

:OUTPut Commands

Use these commands to control the output parameters of the module. These
include jitter amplitude and frequency.

. The module must be selected with the INSTrument:SELect command prior

to using these commands.

Summary of Contents for HDST1 HD-SDI

Page 1: ...User Manual HDST1 HD SDI Stress Test Module 070 A880 51 www tektronix com...

Page 2: ...and foreign patents issued and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved Tektronix Inc P O Box 50...

Page 3: ...ther locations This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care Tektronix shall not be obligated to furnish service u...

Page 4: ......

Page 5: ...and Commands Syntax 3 1 Programming Model 3 1 SCPI Commands and Queries 3 3 Functional Command Groups 3 5 Output 3 5 OUTPut Commands 3 7 Command Tree 3 8 OUTPut STATe 3 9 OUTPut SERial AMPLitude 3 10...

Page 6: ...st Module User Manual Appendices Appendix A Specifications A 1 Appendix B SCPI Conformance Information B 1 Appendix C Installation C 1 Service Safety Summary C 1 Preventing Component Damage C 2 Module...

Page 7: ...4 Figure C 2 Top cover removal C 5 Figure C 3 Removing the rear panel C 6 Figure C 4 Module flange C 6 Figure C 5 Installing the module C 7 Figure C 6 Top screw C 8 List of Tables Table 1 1 Standard a...

Page 8: ...Table of Contents HDST1 HD SDI Stress Test Module User Manual...

Page 9: ...t have it inspected by qualified service personnel Terms in this Manual These terms may appear in this manual Warning statements identify conditions or practices that could result in injury or loss of...

Page 10: ...eneral Safety Summary vi HDVG1 HDTV Digital Video Generator Refer to the specifications section for a listing of certifications and compliances that apply to this product Certifications and Compliance...

Page 11: ...s The following documents are also available The HDST1 HD SDI Stress Test Module Service Manual describes how to service the module This optional manual must be ordered separately The TG2000 Signal Ge...

Page 12: ...ix com Sales support 1 800 833 9200 select option 1 Service support 1 800 833 9200 select option 2 Technical support Email techsupport tektronix com 1 800 833 9200 select option 3 6 00 a m 5 00 p m Pa...

Page 13: ...Getting Started...

Page 14: ......

Page 15: ...ion Platform The TG2000 Platform must be running version 2 2 or later firmware The module is an HD stress test module which provides HDTV interface stressing functions The module contains the followin...

Page 16: ...al 070 A881 XX Option This subsection describes the option available for the HDST1 module The following option is available Option D1 Test data report A calibration test data report will be provided w...

Page 17: ...e 5 Use the 75 W BNC cable to connect the STRESS OUT connector on the HDST1 module and the input connector on the HDTV waveform monitor 6 Use the 75 W terminator to terminate the other loop through co...

Page 18: ...Getting Started HDST1 HD SDI Stress Test Module User Manual...

Page 19: ...Operating Basics...

Page 20: ......

Page 21: ...TG2000 Signal Generation Platform refer to the TG2000 Signal Generation Platform User Manual before reading this section Basic Module Operations Figure 2 1 shows the menu structure for basic module op...

Page 22: ...ital signal for stress tests The signal parameters can be changed from a window menu and the front panel controls In addition this connector can be used to output a clock signal for calibrating an ext...

Page 23: ...st Module User Manual 2 3 Operating Procedures This section is organized into the following main topics Power on the mainframe and select the module Module parameters Refer to Figure 2 1 on page 2 1 f...

Page 24: ...self tests are complete the instrument displays icons representing the generator modules If an installed module is not represented refer to Troubleshooting in the HDST1 HD SDI Stress Test Module Servi...

Page 25: ...eters window shown below To enter the Module Parameters window for the HDST1 module follow these steps 1 Select the HDST1 module if not already selected The Module Parameters window appears as shown b...

Page 26: ...1 steps Jitter HF Freq Sets the frequency of the high frequency jitter added to the output signal You can set the value from 0 1 Hz to 10 MHz in 0 1 Hz steps Jitter HF Ampl Sets the amplitude of the h...

Page 27: ...steps 4 Enter a value using the knob or keypad 5 If you want to reset all the parameters to the default value touch Reset 6 Touch Quit to exit the window To enable or disable the module output follow...

Page 28: ...e output when the error rate setting in the SDI parameters window is set to more than or equal to 0 1 To output the calibration signal follow these steps 1 In the Module Parameters window shown on pag...

Page 29: ...Syntax and Commands...

Page 30: ......

Page 31: ...s and will be accepted without a reported error 2 Enable the module using the command The output state of the module must be enabled before test signal parameters can be changed Many commands will acc...

Page 32: ...return the maximum acceptable value DEFault Use this argument to return the default value The following series of commands and arguments demonstrate the effect of each 1 Enter INSTrument SELect HDST1...

Page 33: ...ing messages instrument responses and data format across all SCPI instruments regardless of manufacturer The HDST1 module uses a command language based on the SCPI standard The SCPI language is based...

Page 34: ...Syntax HDST1 HD SDI Stress Test Module User Manual...

Page 35: ...TPut SERial AMPLitude STEP Set or query output amplitude step size OUTPut SERial DUTY Set or query output duty cycle OUTput SERial ERATe Set or query error rate OUTput SERial JITTer HF AMPLitude Set o...

Page 36: ...Functional Command Groups HDST1 HD SDI Stress Test Module User Manual...

Page 37: ...er Manual 3 7 OUTPut Commands Use these commands to control the output parameters of the module These include jitter amplitude and frequency The module must be selected with the INSTrument SELect comm...

Page 38: ...TATe boolean SERial AMPLitude numeric_value STEP numeric_value DUTY numeric_value ERATe numeric_value JITTer HF AMPLitude numeric_value STEP numeric_value FREQuency numeric_value STEP numeric_value LF...

Page 39: ...his command to set or query the state of the HDST1 module output signal OUTPut STATe boolean OUTPut STATe Command Query response ON None None Command OUTP STAT ON Query OUTP STAT Response 1 None Synta...

Page 40: ...ut signal The units are a percent of the 800 mV amplitude OUTPut SERial AMPLitude numeric_value OUTPut CIRCle AMPLitude Command Query response 100 200 Execution error None Command OUTP SER AMPL 90 Que...

Page 41: ...amplitude of the output signal The units are percent OUTPut SERial AMPLitude STEP numeric_value OUTPut SERial AMPLitude STEP Command Query response 1 200 Execution error None Command OUTP SER AMP STEP...

Page 42: ...the duty cycle of the output signal The units are percent OUTPut SERial DUTY numeric_value OUTPut SERial DUTY Command Query response 50 0 200 Execution error None Command OUTP SER DUTY 60 Query OUTP...

Page 43: ...rrors error rate inserted into the output signal The units are errors second OUTPut SERial ERATe numeric_value OUTPut SERial ERATe Command Query response 0 0 200 Execution error None Command OUTP SER...

Page 44: ...the output signal The units are unit intervals UI OUTPut SERial JITTer HF AMPLitude numeric_value OUTPut SERial JITTer HF AMPLitude Command Query response 0 0 200 Execution error None Command OUTP SER...

Page 45: ...cy jitter The units are unit intervals UI OUTPut SERial JITTer HF AMPLitude STEP numeric_value OUTPut SERial JITTer HF AMPLitude STEP Command Query response 0 01 200 Execution error None Command OUTP...

Page 46: ...the output signal The units are Hertz OUTPut SERial JITTer HF FREQuency numeric_value OUTPut SERial JITTer HF FREQuency Command Query response 1000000 0 200 Execution error None Command OUTP SER JITT...

Page 47: ...requency jitter The units are Hertz OUTPut SERial JITTer HF FREQuency STEP numeric_value OUTPut SERial JITTer HF FREQuency STEP Command Query response 0 01 200 Execution error None Command OUTP SER JI...

Page 48: ...the output signal The units are unit intervals UI OUTPut SERial JITTer LF AMPLitude numeric_value OUTPut SERial JITTer LF AMPLitude Command Query response 0 1 200 Execution error None Command OUTP SER...

Page 49: ...cy jitter The units are unit intervals UI OUTPut SERial JITTer LF AMPLitude STEP numeric_value OUTPut SERial JITTer LF AMPLitude STEP Command Query response 0 01 200 Execution error None Command OUTP...

Page 50: ...o the output signal The units are Hertz OUTPut SERial JITTer LF FREQuency numeric_value OUTPut SERial JITTer LF FREQuency Command Query response 10 0 200 Execution error None Command OUTP SER JITT LF...

Page 51: ...equency jitter The units are Hertz OUTPut SERial JITTer LF FREQuency STEP numeric_value OUTPut SERial JITTer LF FREQuency STEP Command Query response 0 1 200 Execution error None Command OUTP SER JITT...

Page 52: ...OUTPut Commands HDST1 HD SDI Stress Test Module User Manual...

Page 53: ...Appendices...

Page 54: ......

Page 55: ...1 Electrical specifications Characteristic Performance requirements Reference information Input Number of outputs 1 BNC Signal HD SDI serial digital interface 1 485 Gbps or 1 485 1 001 Gbps 800 mVp p...

Page 56: ...ency jitter Amplitude 0 UI to 20 UI Resolution 0 01 UI Amplitude error typical t0 1 UI 1 Measured at 8 UI v1 kHz t0 1 UI 5 Measured at 8 UI v5 kHz t0 1 UI 10 Measured at 8 UI v10 kHz Frequency 0 1 Hz...

Page 57: ...ld Emissions EN 55022 Class A1 Radiated and Conducted EN 61000 3 2 Power Line Harmonics EN 55103 2 Immunity EN 55103 2 Annex A Radiated Magnetic Field Immunity IEC 61000 4 2 Electrostatic Discharge Im...

Page 58: ...Appendix A Specifications HDST1 HD SDI Stress Test Module User Manual...

Page 59: ...ll commands supported by the module The columns to the right show whether a command is defined in the SCPI 1994 0 Standard or not Table B 1 SCPI Conformance information Command Defined in SCPI 1994 0...

Page 60: ...Appendix B SCPI Conformance Information HDST1 HD SDI Stress Test Module User Manual...

Page 61: ...for the procedures Service Safety Summary Only qualified personnel should perform service procedures Read this Service Safety Summary and the General Safety Summary before performing any service proce...

Page 62: ...Platform mainframe 2 Transport and store the modules in a static protected bag or container 3 Do not slide the module over any surface 4 Handle modules as little as possible 5 Do not touch module com...

Page 63: ...t the TG2000 Platform mainframe rear panel power switch to off Unplug the power cord 2 Select the slot you will use to install the module Table C 1 lists the slot restrictions Figure C 1 shows a sampl...

Page 64: ...dule AWVG1 Module Clock Module BG1 Module Power Supply HDVG1 Module HDST1 Module Figure C 1 Rear panel slot numbering To avoid a shock hazard always remove the power cord before removing the top cover...

Page 65: ...Appendix C Installation HDST1 HD SDI Stress Test Module User Manual C 5 Figure C 2 Top cover removal...

Page 66: ...as shown in Figure C 3 Loosen but do not remove the bottom screw You will use it later to secure the module Figure C 3 Removing the rear panel 5 While ensuring correct alignment of the module flange a...

Page 67: ...module The connectors must exactly match before you attempt to press the module firmly in place If the connectors do not match you could bend a pin that could damage the module mainframe or both when...

Page 68: ...rear panel power switch to ON and pressing the front panel power switch 14 Wait for the instrument to perform self tests Module Removal A T 10 torx tip screwdriver is the only tool you need to remove...

Page 69: ...m screw You will use it later to secure the rear panel 5 Refer to Figure C 6 on page C 8 and remove the top screw 6 Remove the module To leave the slot empty proceed to step 8 of this procedure 7 To i...

Page 70: ...Appendix C Installation HDST1 HD SDI Stress Test Module User Manual...

Page 71: ......

Page 72: ......

Page 73: ...rs 2 5 Module Utility 2 8 Module Utility window 2 8 Modules window 2 4 O Online help 2 2 Option 1 2 Output signal enable 2 7 P Phone number Tektronix viii Power on procedure 2 4 Product description 1...

Page 74: ...Index Index 2 HDST1 HD SDI Stress Test Module User Manual Window Module Parameters 2 5 Module Utility 2 8 Modules 2 4 SDI Parameters 2 6...

Page 75: ......

Page 76: ......

Reviews: