Commands Listed in Alphabetical Order
than
argument sets the oscilloscope to trigger if the a runt pulse is detected with
width than the time set by the
SEARCH:SEARCH<x>:TRIGger:A:RUNT:WIDth
command.
EQUal
argument sets the oscilloscope to trigger when the pattern is true for a time
period equal to the time period speci
fi
ed in
within a ±5% tolerance.
NOTEQual
argument sets the oscilloscope to trigger when the pattern is true for a
time period greater than or less than (but not equal) the time period speci
fi
ed in
SEARCH:SEARCH<x>:TRIGger:A:RUNT:WIDth
within a ±5% tolerance.
SEARCH:SEARCH<x>:TRIGger:A:RUNT:WIDth
Sets or returns the width setting for a runt trigger search to determine where to
place a mark. <x> is the search number.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:RUNT:WIDth <NR3>
SEARCH:SEARCH<x>:TRIGger:A:RUNT:WIDth?
Arguments
<NR3>
speci
fi
es the minimum width, in seconds.
SEARCH:SEARCH<x>:TRIGger:A:SETHold:CLOCk:EDGE
Sets or returns the clock slope setting for a setup/hold trigger search to determine
where to place a mark. <x> is the search number.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
SEARCH:SEARCH<x>:TRIGger:A:SETHold:CLOCk:EDGE?
Arguments
FALL
speci
fi
es polarity as the clock falling edge.
RISe
speci
fi
es polarity as the clock rising edge.
MSO4000 and DPO4000 Series Programmer Manual
2-397
Summary of Contents for DPO4000 Series
Page 2: ......
Page 10: ...Table of Contents vi MSO4000 and DPO4000 Series Programmer Manual ...
Page 23: ...Command Syntax MSO4000 and DPO4000 Series Programmer Manual 2 9 ...
Page 24: ...Command Syntax 2 10 MSO4000 and DPO4000 Series Programmer Manual ...
Page 84: ...Command Groups 2 70 MSO4000 and DPO4000 Series Programmer Manual ...
Page 546: ...Commands Listed in Alphabetical Order 2 532 MSO4000 and DPO4000 Series Programmer Manual ...
Page 564: ...Status and Events 3 18 MSO4000 and DPO4000 Series Programmer Manual ...
Page 565: ...Appendix A Character Set MSO4000 and DPO4000 Series Programmer Manual A 1 ...
Page 566: ...Appendix A Character Set A 2 MSO4000 and DPO4000 Series Programmer Manual ...
Page 572: ...Appendix B Reserved Words B 6 MSO4000 and DPO4000 Series Programmer Manual ...