Set the FastFrame analyze tab controls
From the Horiz /Acq menu, select FastFrame; then open the Analyze tab.
Overview. Use the
Analyze tab to select the viewing frame (Selected Frame) when FastFrame is
turned on. You can also select the reference frame.
To use.
1. Select the Source channel from the drop-down list, and then use the multipurpose knob to select the Reference Frame.
2. Select the Source channel from the drop-down list, and then use the multipurpose knob to identify the Selected Frame.
3. Click the
Table Save button to display the Save As dialog box and save FastFrame time stamps in a table
format.
Behavior. The Selected Frame displays the frame of interest. The Selected Frame can use any Channel, Math, or Reference
waveform as the source waveform. The instrument will display one frame at a time. You can use the Selected Frame control to
scroll through all of the frames until you find the frame of interest.
TIP. Use the Reference frame to establish a reference frame when using time stamps. You can view the time stamps by turning
on the readouts.
Time delta between frames. You can calculate the Time Delta (differences) between Frames and display those differences.
These time stamps are displayed in a format that shows the date and time. The Timestamp Table displays the current time
stamps and readout information. This table is read-only.
Frame
A frame is a segment of the entire data record. When used with FastFrame, each segment contains all of the data of a single
acquisition. Each captured event is stored sequentially in its own frame. The frames appear in the order they were captured.
Time stamp readout format
The Time Stamp readouts are displayed in the following format:
Day/Month/Year/ Hours/Minutes/Seconds/ Milliseconds/Microseconds/Nanoseconds/Picoseconds
Frame finder. Set up the Frame Finder to search for individual frames; then click Start to initiate the search.
What do you want to do next?
Go to the Horizontal Setup control window.
Return to the Acquisition Setup control window.
Time stamps. Time stamps are a convenient way of measuring the time between triggers when using FastFrame.
Oscilloscope reference
DPO70000SX, MSO/DPO70000DX, MSO/DPO70000C, DPO7000C, and MSO/DPO5000B Series
801
Summary of Contents for DPO2304SX
Page 1: ...Tektronix Digital Phosphor Oscilloscopes Printable Help P077006219 077 0062 19...
Page 2: ......
Page 3: ...Tektronix Digital Phosphor Oscilloscopes Printable Help www tek com 077 0062 19...
Page 32: ...Introduction xxviii DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 130: ...Cursor setups 98 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 198: ...MagniVu setup 166 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 212: ...Display setups 180 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 300: ...Math setups 268 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 408: ...MyScope setups 376 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 510: ...Trigger setups 478 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 548: ...Vertical setups 516 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 605: ...Utilities DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series 573...
Page 606: ...Utilities 574 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 920: ...Index 888 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...