background image

Programmable Interface  

GPIB:

 IEEE 488.2-1987 compatible.  

RS-232:

 9-Pin D connector.  

Environmental  

Temperature:

 

Operating: +10 to +40 degrees C. 
Nonoperating: -20 to +60 degrees C.  

Humidity:

 

Operating: 20% to 80% (no condensation). 
Nonoperating: 5% to 90% (no condensation).  

Altitude:

 

Operating: To 4.5 km (15,000 ft.). Maximum operating temperature decreases 1 degrees C for each 300 
m above 1.5 km. 
Nonoperating: To 15 km (50,000 ft.).  

Vibration:

 Operating: 0.33 mm p-p, 10 Hz to 55 Hz for 15 minutes.  

Shock:

 Nonoperating: 30 g (1/2 sine) 11 ms duration.  

Bench Handling:

 Operating: Drop from 10 cm (4 in.) tilt or 45 degrees, whichever is less.  

EMC: Emissions:

 Within limits of FCC CFR 47, Part 15, Subpart B, Class A; VFG 243; EN55022, 

B;EN6055-2. Immunity: Within limits of IEC 801-3, IEC 801-2, IEC 801-4.  

Electrical Discharge:

 Operating Max Test Voltage: 15 kV (150 pF through 150 ohm).  

Safety:

 Designed to meet UL 1244 and CSA 22.2 No. 231.EEC certified.  

Power  

Source Power:

 

Voltage Ranges: 90 to 127 VAC or 90 to 250 VAC. 
Line Frequency: 90 to 127 V, 48 to 440 Hz; 90 to 250 V, 48 to 63 Hz.  

Maximum Current:

 4 A at 50 Hz, 90 V.  

Maximum Power Dissipation:

 300 W.  

Fuse Rating:

 UL 198.6 (3 AG): 6 AFAST, 250 V. IEC 127:5 A (T), 250 V.  

Physical Characteristics  

Dimensions:

 

Width (with handle): 362 mm 14.3 inch 
Height (with feet): 164 mm, 6.4 inch 
Length (with front cover): 491 mm, 19.25 inch 
Length (with handle extended): 576 mm, 22.2 inch 
Net Weight: 10.7 kg, 23.6 lb.  

Ordering Information  

AWG 2040 1 GS/s Arbitrary Waveform Generator 

Page 5 of 7

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

9/27/2007

http://ftp.tektronix.com/Measurement/Products/catalog/archive/ca-AWG2040/index.html

Summary of Contents for AWG 2040

Page 1: ...Automatic Test Sequences with Waveform Sequencing Formula Entry of Parameters for Mathematically Precise Waveforms Fully Programmable from Front Panel RS 232 or GPIB IEEE 488 2 Applications Broadcast...

Page 2: ...m sequence up to 65 536 times Gated Same as continuous mode except period is executed only for the duration of the gated signal until the sequence started is completed Waveform Advance Output quiescen...

Page 3: ...low pass Risetime 10 MHz 35 ns 20 MHz 17 ns 50 MHz 7 0 ns 100 MHz 3 5 ns Delay from Marker 10 MHz 42 ns 20 MHz 22 ns 50 MHz 12 ns 100 MHz 7 0 ns Through 2 5 ns Auxiliary Outputs Marker Number of Mark...

Page 4: ...Trig Threshold Level TTL Level Pulse Width 100 ns minimum Maximum Input Volts 5 V to 0 V Delay 100 ms maximum Impedance 10 kilohm Connector SMB External Clock Sensitivity 400 mVp p 4 0 dBm Maximum In...

Page 5: ...ty Within limits of IEC 801 3 IEC 801 2 IEC 801 4 Electrical Discharge Operating Max Test Voltage 15 kV 150 pF through 150 ohm Safety Designed to meet UL 1244 and CSA 22 2 No 231 EEC certified Power S...

Page 6: ...ration Services International Power Plug Options Opt A1 Universal Euro 220 V 50 Hz Opt A5 Switzerland 220 V 50 Hz Accessories Accessory Pouch Order 016 1159 00 Front Cover Order 200 3232 00 RS 232 C C...

Page 7: ...Careers International myTek Copyright Tektronix Inc Terms of Use Privacy Statement Sitemap Learn More Page 7 of 7 Tektronix Products AWG 2040 Arbitrary Waveform Generator 9 27 2007 http ftp tektronix...

Reviews: