background image

TEKTINO

RCC-6S-dual USER MANUAL V2.30

14/20

During

recovery,

vacuum pump is
pressurized.

After

period too much oil
in vacuum pump

The contact between solenoid valve
#8 and valve base is not well sealed.

Remove solenoid #8 from valve
base, clean the solenoid valve and

valve base.

During

vacuum,

there is suction in old
oil bottle.

The contact between solenoid valve
#2 and valve base is not well sealed.

Remove solenoid #2 from valve base, clean

the solenoid valve and valve base.

Remarks: Regular maintenance by specialized technicians may largely reduce machine failure.

Summary of Contents for RCC-6S-dual

Page 1: ...TEKTINO RCC 6S Dual User Manual RCC 6S dual USER MANUAL...

Page 2: ...ance recommended self troubleshooting and convenient USB upgrade etc General safety The storage cylinder in this unit contains liquid refrigerant Overfilling of the cylinder can cause violent explosio...

Page 3: ...FUNCTION TABLE 3 PART DESCRIPTION 4 OPERATION PREPARATIONS 5 EQUIPMENT CONNECTION Recovery vacuum oil injection charge auto mode 7 RECOVERY 8 VACUUM 9 OIL INJECTION 10 CHARGE 11 AUTO MODE 13 SYSTEM S...

Page 4: ...34yf 10KG New oil bottle capacity 250ml Used oil bottle capacity 400ml Dual condensers and cooling fans one for R 134a one for HFO 1234yf Max Pressure 20bar Charge speed 2Kg Min max LCD display 4 3 in...

Page 5: ...efrigerant from equipment gas cylinder to automotive A C system Auto mode Performs the selected functions in a fully automatic sequence The machine will stop automatically once all the selected functi...

Page 6: ...ad LP gauge R134a HFO1234yf Coupler connect fittinggs LCD screen HP gauge Fuse Power switch Vacuum pump New oil vessel Used oil vessel R134a refrigerant tank HFO1234yf Refrigerant tank R134a tank guag...

Page 7: ...When you need transport the machine please screw those bolts on Fill equipment with refrigerant New equipment is empty you need to fill the equipment with refrigerant and refrigeration oil Through tan...

Page 8: ...ned on it reminds to select refrigerant type If the refrigerant type selected is different from the refrigerant handled at previous operation the machine automatically recovers refrigerant inside mach...

Page 9: ...ment Connection For recovery vacuum oil injection charge Auto Mode Warning Except the situations clearly stated in the manual during all equipment operations please maintain the vehicle engine and A C...

Page 10: ...ft connected on the vehicle for a minimum time of 3 minutes longer in cold climates for any pressure increase test If after 3 minutes or longer if possible there is no pressure increase the recovery c...

Page 11: ...nt or by manual injection Manual oil injection is effected by pressing right arrow key on control panel Please be aware that there is no oil load cell equipped in the machine the oil injection volume...

Page 12: ...to do calibration of load cells The load cell calibration is very simple and fast with just one step 1kg weight calibration step Warning Misoperation in calibration could bring about serious conseque...

Page 13: ...ng message Click OpenFile to select update to update e g file RCC9A_V2 01 for main program update or Database_V2 02 for database update Then click Connect the PC displays the following message Click P...

Page 14: ...t maintenance is displayed in the left beneath part of each operation interface Upon 480 operations having been made the machine displays the following message and users can continue using the equipme...

Page 15: ...to service manual 2 Change compressor 3 Fasten pressure sensor connection to PCA or change the pressure sensor No change in recovery volume 1 No refrigerant in A C 2 Support screw of gas cylinder loa...

Page 16: ...e is not well sealed Remove solenoid 8 from valve base clean the solenoid valve and valve base During vacuum there is suction in old oil bottle The contact between solenoid valve 2 and valve base is n...

Reviews: