2.6
Battery Replacement
Open up the Industrial Tracker using a #2 Phillips screwdriver. The Tracker has 12x enclosure Philips
screws at the bottom.
Be careful not to misplace the silicone cover gasket.
Replace the battery(-ies). The Industrial Tracker accepts
D-size, 3.6 V, LTC batteries. The Tracker can
operate with one or two batteries. One battery yields half the capacity of a two-battery module. In
the case of one battery, the battery can be inserted in any of the two battery holders. Suggested
replacement batteries include,
•
Tadiran TL-4930/S or TL-5930/S
•
Xeno Energy XL-205F STD
•
Saft LS33600
Once the Tracker is powered and tries to join (see Section 3.3 for LED behavior), replace the cover and
gasket. Make sure that the gasket is properly seated in the cover before placing on the Tracker
housing. Tighten the 12 cover screws to 2.5 lbf-in (30 N-cm).
To completely turn off the Tracker, the batteries must be uninstalled. To reset the Tracker, the
Tracker must remain unpowered (removing the batteries) for at least 1 minute. Another way to reset
the Tracker is to press the internal reset button on the Tracker PCBA. In this case, after bootup the
Tracker goes to DEEP SLEEP, and can be woken up by applying the magnetic pattern described in
Section 2.4, or by turning the Tracker off (removing the batteries) and on.