TEKTELIC Communications T0006086 User Manual Download Page 1

 

 
 

 

 

 

 

 

 

 

U

SER 

G

UIDE

 

Document Type: 

User Guide 

Document Number: 

T0006377_UG 

Document Version: 

0.5 

Product Name: 

Meeting Room Display Tablet 

Product Codes & 
Revisions: 

T0006086 –Battery Powered Digital Signage, NA 

T0006093 – Externally Powered Digital Signage, NA 

Issue Date: 

Mar 2, 2020 

 

 

 

 

 

 

Summary of Contents for T0006086

Page 1: ...uide Document Number T0006377_UG Document Version 0 5 Product Name Meeting Room Display Tablet Product Codes Revisions T0006086 Battery Powered Digital Signage NA T0006093 Externally Powered Digital S...

Page 2: ...y 17 2019 Emma Tholl Initial Draft 0 2 November 7 2019 C Karperien General updates and template updates 0 3 November 25 2019 A Narayanan Updated to include Tablet specific instructions 0 4 December 5...

Page 3: ...3 1 Included Product and Installation Material 13 3 2 Safety Precautions 13 3 3 Unpacking and Inspection 13 3 4 Equipment Required for Installation 14 3 5 Meeting Room Display Tablet mounting 14 3 6...

Page 4: ...Meeting Room Display Tablet User Guide T0006377_UG Version 0 5 TEKTELIC Communications Inc Confidential Page 4 of 28 8 Bibliography 28...

Page 5: ...splay Tablet User Guide T0006377_UG Version 0 5 TEKTELIC Communications Inc Confidential Page 5 of 28 List of Tables Table 1 Meeting Room Display Tablet Models 7 Table 2 Meeting Room Display Tablet Sp...

Page 6: ...e 15 Figure 3 2 Tablet back side 16 Figure 4 1 Room Available User interface flow 18 Figure 4 2 Room Occupied state 19 Figure 4 3 Room Occupied User interface flow 20 Figure 6 1 USB A to Micro B Cable...

Page 7: ...form front lighting for low light environment LED Configurable RGB LEDs provide an indication of the room status that are visible from a distance LoRa Air interface capable of long range at low power...

Page 8: ...nd provides a low battery warning for timely replacement Deep Sleep mode Accelerometer allows the device to save power when the Tablet is not in use and wake up on when a Double tap is detected on the...

Page 9: ...1024 H x 758 V pixels Color 16 levels of gray monochrome Front light Touch screen Capacitive touch screen 5 mm accuracy Power Source Externally powered Option DC 5V PoE 48VDC IEEE 802 3af Mode A or B...

Page 10: ...nd Figure 1 3 illustrates the customer accessible interfaces of the Tablet All models share the same layout however some functions are not available in some models The externally powered model shown i...

Page 11: ...eting Room Display Tablet User Guide T0006377_UG Version 0 5 TEKTELIC Communications Inc Confidential Page 11 of 28 Figure 1 3 The Tablet Battery interface layout Battery cover screws Battery Pull tab...

Page 12: ...g the Tablet Facility DB Mail server Calendar Book Now Application BNA Network Server Device DB Meeting Room Tablet Gateway LoRa Figure 2 1 Meeting Room Display Tablet s infrastructure 2 1 Power Up Do...

Page 13: ...service center All installation practices must be in accordance with the local and national electrical codes Ensure that the Tablet is located to eliminate any physical hazard to people or property Th...

Page 14: ...mounting surface must be capable of holding 15 kg 33 lbs Mounting the wall plate Thread the Ethernet and or Power cables through the rectangular opening in the wall plate Ensure that the lock screw fe...

Page 15: ...igure 3 2 then push the Tablet onto the plate Slide the Tablet to fix the Tablet in place It is recommended to proceed with the commissioning steps detailed in Commissioning before completing the fina...

Page 16: ...teps for replacing the batteries are as follwos Removed the battery cover by removing two philips screws shown in Figure 1 3 Remove all the old batteries from the device To turn off the device the bat...

Page 17: ...oom is available for booking and one when the room is occupied 4 1 Available When the room is available for booking the GUI uses a light background as shown in Figure 4 1 The LEDs light up with green...

Page 18: ...Meeting Room Display Tablet User Guide T0006377_UG Version 0 5 TEKTELIC Communications Inc Confidential Page 18 of 28 Figure 4 1 Room Available User interface flow...

Page 19: ...Next meeting information Meeting start time and booked by Button to finish the current meeting Button to extend the current meeting for a specified duration o There must be at least 10 minutes in betw...

Page 20: ...Meeting Room Display Tablet User Guide T0006377_UG Version 0 5 TEKTELIC Communications Inc Confidential Page 20 of 28 Figure 4 3 Room Occupied User interface flow...

Page 21: ...fault configuration on the Tablet is Report the battery voltage every 1 one hour For Class A mode operation query room status every 10 minutes 5 3 LED Behaviour Room Status LED on externally powered v...

Page 22: ...n the field See the steps outlined below to update the firmware of your device 6 2 Prerequisites Hardware USB Cable USB A to USB Micro B PC with Windows 10 Figure 6 1 USB A to Micro B Cable Software T...

Page 23: ...Page 23 of 28 Figure 6 2 Digital Signage Board with power plug and USB cable connected Software Setup Start the Tera Term terminal Load settings as shown on Figure 6 3 from the INI setup file Open the...

Page 24: ...ure 6 4 Ports in Device Manager 6 4 Firmware Upgrade 1 Reset the device 2 Wait for the new Serial Device detected in Device Manager may take up to 3 minutes Figure 6 5 New Serial Device in Device Mana...

Page 25: ...ex file with new Firmware image to send Figure 6 7 Figure 6 7 Starting Firmware Upgrade 6 Wait for file transfer completed indicated by Serial upload complete message in the Terminal Figure 6 8 File t...

Page 26: ...d to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in acco...

Page 27: ...mique Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes a L appareil ne doit pas produire de brouillage b L appareil doit accepter to...

Page 28: ...Room Display Tablet Technical Refernce Manual 2019 3 LoRa Alliance LoRaWAN 1 1 Regional Parameters ver 1 1 rev B Jan 2018 4 Tektelic Network Server User Guide 2019 5 LoRa Alliance LoRaWAN 1 02 Region...