TTM 01-G Manual / October 2018
26
String-E Time Code O/P
Table 13 details the String E serial string format and fields.
About
This provides time, year information, and a sync indicator field.
Timing
The string is transmitted once every second, with the leading edge of the “start” bit of the
<CR> exactly on the second.
Default Comms
9600 bps, 8-bit ASCII, no parity
Definition
<SOH>YYYY:ddd:hh:mm:ssQ<CR><LF>
Placeholder
Content
YYYY
4-digit current year
:
HEX 3A
ddd
Day of year: range “001” – “365”
:
HEX 3A
hh
hour: “00” – ”23”
:
HEX 3A
mm
minute: “00” – “59”
:
HEX 3A
ss
seconds: “00” – “59”
Q
Quality character, as defined in String B (refer to Table 11)
<CR>
Carriage Return: HEX 0D
<LF>
Line Feed: HEX 0A
Table 13 - String-E Time Code Format Fields
Example:
Interpretation:
<SOH>2004:112:12:34:36?<CR><LF>
2004, day 112, 12:34:36pm, >100us sync error
Summary of Contents for TTM 01-G