TTM 01-G Manual / October 2018
24
String-C Time Code O/P
Table 12 details the String C serial string format and fields.
About
This code is effectively a combination of String-A and String B. It provides both year
information and a sync indicator field.
Timing
Transmitted once every second. The leading edge of the “start” bit of the first character,
<CR>, is exactly on the second to which the message data refers.
Default Comms
9600 bps, 8-bit ASCII, no parity
Definition
<CR><LF>Q<SPACE>yy<SPACE>ddd<SPACE>hh:mm:ss.000<SPACE><SPACE><SPACE>
Placeholder
Content
<CR>
Carriage Return: HEX 0D
<LF>
Line Feed: HEX 0A
Q
Quality indicator: ‘ ‘ = in
-
sync, ‘?’ = out
-of-sync
<SPACE>
HEX 20 (space)
yy
Year: “00” – “99” representing the last two digits of the year
<SPACE>
HEX 20 (space)
ddd
Day of year: range “001” – “366”
<SPACE>
HEX 20 (space)
hh
hour: “00” – ”23”
:
HEX 3A
mm
minute: “00” – “59”
:
HEX 3A
ss
seconds: “00” – “59”
.000
ASCII “.000”
<SPACE>
HEX 20 (space)
<SPACE>
HEX 20 (space)
<SPACE>
HEX 20 (space)
Table 12 - String C Time Code Format Fields
Example:
Interpretation:
<CR><LF>? 02 112 12:34:36.000
day 112 of year (20)02, time: 12:34:36, out-of-sync