(1)

 

Slave constant-current indicator or two-ways parallel state indication: the LED illuminates when 
the slave output is in current-regulated state or the two adjustable outputs is in parallel. 

(2)

 

Slave constant current adjustment: adjusting salve output current value (adjusting the current-limit 
protection point) 

(3)

 

Slave constant-voltage indicator: the LED illuminates when the slave output is in voltage-
regulated state. 

(4)

 

Slave constant voltage adjustment: adjusting salve output voltage. 

(5)

 

Amp display: indicating slave output current by analog meter or LED (LCD

(6)

 

Volt display: indicating slave output voltage by analog meter or LED (LCD). 

(7)

 

Control switch: for selecting the two adjustable outputs independent, series, parallel. 

(8)

 

Amp display: indicating master output current by analog meter or LED (LCD). 

(9)

 

Control switch: for selecting the two adjustable outputs independent, series, parallel. 

(10)

 

Volt display: indicating master output voltage by analog meter or LED (LCD). 

(11) Master constant-current indicator: the LED illuminates when the master output is in current- 

regulated state. 

(12) Master constant-voltage indicator: the LED illuminates when the master output is in voltage-

regulated state. 

(13) Power switch: the unit is “ON” when this button switch is depressed, while CV LED (3) (12) or 

CC LED (1) (11) illuminating. 

(14) Master constant voltage adjustment: adjusting master output voltage. 
(15) Fixed 5V output terminal (+): connecting the positive terminal of load. 
(16) Fixed 5V output terminal (-): connecting the negative terminal of load. 
(17) Master constant current adjustment: adjusting master output current value (adjusting the current-

limit protection point). 

(18) Master output terminal (+): connecting the positive terminal of load. 
(19) Case ground: connecting the case to ground. 
(20) Master output terminal (-): connecting the negative terminal of load. 
(21) Slave output terminal (+): connecting the positive terminal of load. 
(22) Case ground: connecting the case to ground. 
(23) Slave output terminal (-): connecting the negative terminal of load. 
 