Step-4
Initiate detector registration procedure by one of
2 methods
:
а) using
LT
(step
5
);
b) by closing
contact pads
(step
6
).
Step-5
Initiating Detector Registration Procedure Using LT
:
1)
press the lower LT button and wait until the beam appears;
3)
shine the laser beam on the detector indicator from a distance of
not more than
5 m
(detector cover is removed);
4)
illuminate the indicator for
1 s
.
The detector`s
red
LED lights up for
2 seconds
, then the detector
switches to wireless network search mode and the
white
LED
blinks at a frequency of
5 Hz
.
Step-6
Initiating Detector Registration by
closing (shorting) contact pads
:
1)
Using a screwdriver, shortly (
for
1-2
s
) close the detector
contact pads
.
The
“Waiting for detector registration in
the network
” mode switches ON for
60 s
.
2)
Close the detector
contact pads
again (for not more than
2 s
).
The detector switches to the wireless network search mode, and its
white
indicator blinks
5 times per second.
Step-7
Verify registration procedure:
Once registration procedure completed
successfully
, the
abbreviated name of detector
«WLD»
appears on the screen or
«WLDxxx registered»
notification appears on the control panel`s
screen.
Once registration procedure
failed
, repeat the registration
procedure, i.e. perform steps
3, 5
or
3, 6
.
Step-8
After successful registration of the detector, for long term storage
before its installation, it is allowed to switch the detector
OFF
by
removing the battery or installing a soft isolator.
When power is supplied, there is no need to re-register the detector in
the same wireless network if it was not intentionally removed from the
network through software or control panel.
6.4 Deleting Alerter from Wireless Network
Deletion the detector from wireless network is performed using
Software **
or through Control Panel`s menu.
When deleting detector from wireless network, Control Panel transmits
notification about deletion to detector within
two periods of RF
supervision time.
After receiving the notification detector issues "No
network" notification.
To speed up the deletion procedure:
- close shortly detector`s contact pads
- within 1 minute close and hold closed for 8-10 sec. contact pads
The detector issues "No network" notification to LED and is available
for registration.
7
Installation
7.2
The detector shall be mounted on the floor in the
lowest
place of
a room where flooding possibility is monitored (taking into account
directions of water flow in case of burst water conduits or heating
system pipelines).
7.3
The detector shall be mounted with the contact pads facing
downwards.
7.4
Check
detector
operability
:
- close the contacts pads (e.g., with a wet cloth),
-
make sure “Violation” event is displayed on the display of Astra-Z-
812
М or MSS Astra-Z.
8
Maintenance
To provide for reliable operation of the detector it is recommended to
test and maintain
the detector
at least once a month
in the following
way:
-
inspect integrity of the detector body;
-
check its location;
-
check detector operability as described in 7.3;
-
clean the detector from any dirt accumulated.
9
Labeling
The following data are shown on the label glued to the body:
- manufacturer trademark;
- detector abbreviated designation;
- firmware version;
- month and year of manufacture (last two digits);
- conformity mark (if the conformity certificate is available);
- bar code, duplicating textual data
.
10
EC Conformity Declarations
This product is in conformity with the provisions of:
R&TTE Directive 1999/5/EC, Article 10.5;
EN 60950: 2001 Safety of information technology equipment;
EN 50371 Generic standard to demonstrate the compliance of low-
power electronic and electrical apparatuses with the basic restrictions
related to human exposure to electromagnetic fields (10 MHz - 300
GHz)
– General public;
EN 301489-17 V1.1.1 (09-2000) Electromagnetic Compatibility and
radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC)
standard for radio equipment and services; Part 17: Specific condi-
tions for wideband data Hiperlan equipment;
EN 300220-1 V1.3.1 (2000-09) Electromagnetic compatibility and
Radio spectrum Matters (ERM); Short range devices; Technical char-
acteristics and test methods for radio equipment to be used in the 25
MHz to 1 000 MHz frequency range with power levels ranging up to
500 mW; Part 1: Parameters intended for regulatory purposes.
Construction of the detector provides for protection class IP41.
11
Recycling
11.1 Detector is not a danger to life, human health and the
environment. On expiry of its lifetime recycling is done without taking
special measures to protect the environment.
11.2 Recycling of battery cells should be done by delivering used cells
to a trading organization, service centre, manufacturer, or to an organi-
zation accepting used batteries
.
12 Manufacturer Warranties
12.1 Quality Management System meets provisions of ISO 9001-2011.
12.2
The manufacturer guarantees the compliance of the detector to
specifications on condition that user observes required conditions of
transportation, storage, installation and operation.
12.3
The storage warranty period is 5 year and 6 months from the date
of manufacture
.
12.4
The operating warranty period is 5 year from the date of commis-
sioning, but not more than 5 year and 6 months from the date of manu-
facture
.
12.5 The manufacturer shall repair or replace a faulty detector during
the warranty period.
12.6 The warranty becomes void if
:
-
the user does not follow guidelines of the operating manual;
-
the detector is mechanically damaged;
-
the detector is repaired by a party other than the Manufacturer.
12.7 The warranty covers the detector only. All equipment manufac-
tured by other parties and used with the detector, including batteries, is
covered by its respective warranty.
The manufacturer bears no responsibility for death, injury, prop-
erty damage or other incidental or premeditated loss based on
user's statement that the device failed to implement its functions
.
* Available for free downloading from
www.controlex.eu
and/or integrated with configuring software.
** Available for free downloading from
www.controlex.eu
.
Sales:
Controlex GmbH
Warranty service and
technical support:
ТЕКО-TD
Philosophenweg 31-33
47051 Duisburg, Germany
Phone: +49 (0) 203 / 393 91 188
Fax: +49 (0) 203 / 393 91 189
GSM: +49 (0) 178 / 218 48 22
E-mail:
Web:
www.controlex.eu
Prospekt Pobedy str. 19
420138 Kazan, Russia
Phone: +7 (843) 261-55-75
Fax: +7 (843) 261-58-08
E-mail:
Web:
www.teko.biz
Made in Russia