teko Astra-Z-3645 Operating Manual Download Page 2

Rev. 3645-v1_5_en

 

Step-4

 

  

Initiate detector registration procedure by one of 

2 methods

:  

а)  using 

LT 

(step 

5

); 

b) by closing 

contact pads 

(step 

6

).

 

Step-5

   

Initiating Detector Registration Procedure Using LT

:  

1)

 press the lower LT button and wait until the beam appears; 

3)

 shine the laser beam on the detector indicator from a distance of 

not more than 

5 m

 (detector cover is removed); 

4)

 illuminate the indicator for 

1 s

.  

The detector`s 

red

 LED lights up for 

2 seconds

, then the detector 

switches  to  wireless  network  search  mode  and  the 

white 

LED 

blinks at a frequency of 

5 Hz

.

 

Step-6

 

  

Initiating  Detector  Registration  by 
closing (shorting) contact pads

1) 

Using  a  screwdriver,  shortly  (

for

 

1-2 

s

) close the detector 

contact pads

.

 

 

The 

“Waiting  for  detector  registration  in 

the network

” mode switches ON for 

60 s

.

 

2) 

Close  the  detector 

contact  pads

 

again (for not more than 

2 s

). 

The detector switches to the wireless network search mode, and its 

white 

indicator blinks 

5 times per second.

 

Step-7

   

Verify registration procedure: 

 

Once  registration  procedure  completed 

successfully

,  the 

abbreviated  name  of  detector 

«WLD»

  appears  on  the  screen  or 

«WLDxxx  registered»

  notification  appears  on  the  control  panel`s 

screen. 

 

Once  registration  procedure 

failed

,  repeat  the  registration 

procedure, i.e. perform steps 

3, 5

 

or 

3, 6

Step-8

 

   

After  successful  registration  of  the  detector,  for  long  term  storage 
before  its  installation,  it  is  allowed  to  switch  the  detector 

OFF

  by 

removing the battery or installing a soft isolator. 
When power is supplied, there is no need to re-register the detector in 
the same  wireless network if it  was not intentionally  removed from the 
network through software or control panel.

 

 

6.4  Deleting Alerter from Wireless Network 

 

 

Deletion  the  detector  from  wireless  network  is  performed  using 

Software **

 or through Control Panel`s menu.

 

When deleting detector from wireless network, Control Panel transmits 
notification  about  deletion  to  detector  within 

two  periods  of  RF 

supervision  time. 

After  receiving  the  notification  detector  issues  "No 

network" notification. 

 

To speed up the deletion procedure: 

- close shortly detector`s contact pads 
- within 1 minute close and hold closed for 8-10 sec. contact pads 
The  detector  issues  "No  network"  notification  to  LED  and  is  available 
for registration.

 

 

Installation 

 

7.2 

 The detector shall be mounted on the floor in the 

lowest

 place of 

a  room  where  flooding  possibility  is  monitored    (taking  into  account 
directions  of  water  flow  in  case  of  burst  water  conduits  or  heating 
system pipelines). 

7.3 

 The  detector  shall  be  mounted  with  the  contact  pads  facing 

downwards.  

7.4 

 Check 

detector

 operability

-  close the contacts pads (e.g., with a wet cloth),  

make  sure  “Violation”  event  is  displayed  on  the  display  of  Astra-Z-

812

М or MSS Astra-Z. 

 

 

Maintenance 

 

To  provide  for  reliable  operation  of  the  detector  it  is  recommended  to 

test and maintain 

the detector 

at least once a month

 in the following 

way: 

-

  inspect integrity of the detector body; 

-

  check its location; 

-

  check detector operability as described in 7.3; 

-

  clean the detector from any dirt accumulated. 

 

9

  

Labeling

 

 

 

The following data are shown on the label glued to the body: 

- manufacturer trademark; 
- detector abbreviated designation; 
- firmware version; 
- month and year of manufacture (last two digits); 

- conformity mark (if the conformity certificate is available); 
- bar code, duplicating textual data

 

10

 

EC Conformity Declarations

 

 

This product is in conformity with the provisions of: 
R&TTE Directive 1999/5/EC, Article 10.5; 
EN 60950: 2001 Safety of information technology equipment; 
EN  50371  Generic  standard  to  demonstrate  the  compliance  of  low- 
power electronic and electrical apparatuses with the basic restrictions 
related  to  human  exposure  to  electromagnetic  fields  (10  MHz  -  300 
GHz) 

– General public;  

EN  301489-17  V1.1.1  (09-2000)  Electromagnetic  Compatibility  and 
radio  spectrum  Matters  (ERM);  Electromagnetic  Compatibility  (EMC) 
standard  for  radio  equipment  and  services;  Part  17:  Specific  condi-
tions for wideband data Hiperlan equipment;  
EN  300220-1  V1.3.1  (2000-09)  Electromagnetic  compatibility  and 
Radio spectrum Matters (ERM); Short range devices; Technical char-
acteristics and test methods for radio equipment to be used in the 25 
MHz  to  1  000  MHz  frequency  range  with  power  levels  ranging  up  to 
500 mW; Part 1: Parameters intended for regulatory purposes. 
Construction of the detector provides for protection class IP41.

 

 

11

 

Recycling

 

 

11.1  Detector  is  not  a  danger  to  life,  human  health  and  the 
environment.  On  expiry  of  its  lifetime  recycling  is  done  without  taking 
special measures to protect the environment. 
11.2 Recycling of battery cells should be done by delivering used cells 
to a trading organization, service centre, manufacturer, or to an organi-
zation accepting used batteries

 

12 Manufacturer Warranties 

 

12.1 Quality Management System meets provisions of ISO 9001-2011. 
12.2

 

The  manufacturer  guarantees  the  compliance  of  the  detector  to 

specifications  on  condition  that  user  observes  required  conditions  of 
transportation, storage, installation and operation.  
12.3

 

The storage warranty period is 5 year and 6 months from the date 

of manufacture

12.4

 

The operating warranty period is 5 year from the date of commis-

sioning, but not more than 5 year and 6 months from the date of manu-
facture

12.5  The  manufacturer  shall  repair  or  replace  a  faulty  detector  during 
the warranty period.   

12.6 The warranty becomes void if

:  

the user does not follow guidelines of the operating manual; 

the detector is mechanically damaged;  

the detector is repaired by a party other than the Manufacturer. 

12.7  The  warranty  covers  the  detector  only.  All  equipment  manufac-
tured by other parties and used with the detector, including batteries, is 
covered by its respective warranty. 

The  manufacturer  bears  no  responsibility  for  death,  injury,  prop-
erty  damage  or  other  incidental  or  premeditated  loss  based  on 
user's statement that the device failed to implement its functions

 
 

*  Available  for  free  downloading  from 

www.controlex.eu

 

and/or integrated with configuring software. 
** Available for free downloading from 

www.controlex.eu

.

 

 

 

 

 

 

 

Sales: 

Controlex GmbH

 

Warranty service and  
technical support: 

ТЕКО-TD 

 

Philosophenweg 31-33 
47051 Duisburg, Germany 
Phone: +49 (0) 203 / 393 91 188 
Fax:     +49 (0) 203 / 393 91 189 
GSM:   +49 (0) 178 / 218 48 22 
E-mail: 

[email protected]

  

Web:    

www.controlex.eu

 

 

Prospekt Pobedy str. 19 
420138 Kazan, Russia 
Phone: +7 (843) 261-55-75 
Fax:     +7 (843) 261-58-08 
E-mail: 

[email protected] 

            [email protected]

 

Web:    

www.teko.biz

  

 

Made in Russia

 

 

Reviews: