teko Astra-8 User Manual Download Page 2

 

Plug 

Jumper 

position 

“Alarm  memory” 
ON 

 

 

 

“Alarm  memory” 
OFF

 

Mem 

 

 

 

AC-channel 
TEST 

Tst 

See sec. 9 

 

6  INSTALLATION PLACE 

 

1) 

   

Recommended  installation  height  is 

2.4-3.6 

m

 and at a distance not more than 

6m

 from the 

most distant spot of protected glass

.

 

2) 

Detector  should  be  installed  on  the  ceiling 

(or  any  other  horizontal  surface) 

strictly

 

horizontally

 

3) 

The  detector  cannot  be  used  in  premises 

with high level of acoustic interference. 

4) 

Alarm  loop  and  power  supply  wires  should 

be located far from power cables.

 

 

To eliminate false alarm hazards

 

1) 

It  is  recommended  to  close  all  doors,  air-

vents, switch off possible sourses of intense air 
flows (fans, air-conditioners)

 and 

acoustic inter-

ferences

 (

loudspeakers

, etc.) 

in the room during 

protection period

.

 

2) 

The  detector's  location  should  provide  di-

rect visibility of all secured glass parts; masking 
the  detector  with  decorative  curtains  is  not  al-
lowed, as sensitivity may be lost

.

 

 

Not recommended installation places 

 

 

 

7 INSTALLATION PROCEDURE  

 

 

1) 

Remove cover

  

 

 

2) 

Remove PCB 
 

 

3) 

Install on the ceiling

 

 

 

 

4) 

Install PCB and perform wiring

 

(see sec.

8

)

 

 

5) 

Perform AC-channel and IR-channel testing 
(see sec.

9

)

 

8  WIRING 

 

Perform  wiring  to  detector`s  terminals  in 
accordance with control panel operating manual. 

 

TMP 

– 

detector tampering control terminals; 

RELAY-PIR, RELAY-GB 

 terminals for detector 

connection to alarm loop; 

+12V, GND 

 power supply terminals.

 

 
 

9  TESTING 

AC-channel: 

 

1) 

Remove jumpers from

 Mem 

and

 GB 

plugs,

 

install jumper on 

Ind

 plug.

  

2) 

Power detector ON. LED starts flash during 

60

 

sec.

 

3) 

During  this  time  close  shortly 

Тst 

plug  using 

screwdriver. 

AC-channel  TEST 

mode  switches 

for 

8 min.

 

4) 

Close detector.

 

5) 

Apply  non-destructive 

strike  to  the  most  distant 
part  of  the  protected 
glass.  

6) 

At 

the 

detection 

moment  LED  should  light 
up  for 

4s

  and  relay 

shou

l

d

  open  (check  with 

control  panel)  or  LED  should  double-flash  one 
time

 

IR-channel: 

Perform 

TEST-pass.  

To detect sensitive zones 
pass  through  detection 
zone  with  the  speed  of 
0.3-3  m/s.  Make  sure  the 

"Alarm  -  IR"

  notification 

is issued with each pass

 

 