6  REGISTRATION 

ATTENTION! 

When registering a detector in the receiver, the 
frequency of the detector and the receiver must 
match.

 

1) 

Remove  the  detector 

cover  by  pushing  the 
cover  latch  out  of  the 
base groove. 

2)

  Pull  out  the  battery 

insulator  or  install  the  battery,  observing  the 
polarity. 

3)

  By closing the 

Lit

 contact with a screwdriver, 

set  the  required  operating  frequency  of  the 
detector  in  accordance  with  the  receiver

’s  fre-

quency 

1x flash

 

– frequency 1 set  

3x flash

 

– frequency 3 set 

4)

  Start  the  registration  mode  on  the  receiver 

according to the method  described  in the  Man-
uals. 
The mode starts for 

45-60 sec

5)

 Power on the detector by removing and rein-

stalling  the  battery. Wait  at  least 20  sec  before 
power on again. 
In case of unsuccessful registration, remove the 
battery and repeat the procedure. 

6)

  Check  the  registration,  according  to  the 

method described in the Manuals.

 

7  INSTALLATION PLACE 

1) 

   Recommended installation height is 

2.3-2.5  m

  and  at  a  distance  not  more  than 

6m

 

from the most distant point of protected glass.

 

2) 

The  detector  cannot  be  used  in  premises 

with high level of acoustic interference

 

 

To eliminate false alarms

 

1) 

It  is  recommended  to  close  all  doors,  air-

vents, switch off possible sourses of intense air 
flows (fans, air-conditioners)

 and 

acoustic inter-

ferences

 (

loudspeakers

, etc.) 

in the room during 

protection period.

 

2) 

The  detector's  location  should  provide  di-

rect visibility of all secured glass parts; masking 
the  detector  with  decorative  curtains  is  not  al-
lowed, as sensitivity may be lost

.

 

 

8  INSTALLATION ORDER  

1) 

Fix the bracket

 

 

 

2) 

Power  on  the  de-

tector  if  it  was  previ-
ously  turned  off  (see 
p. 6, steps 1) and 2)). 
 

3) 

Close 

detector

’s 

cover.

 

4) 

Mount  the  detector  on the 

bracket, aligning the grooves 
for the bracket on the detec-
tor  base  with  the  bracket 
latches  and  pushing  the 
base  until  it  stops  (until  it 
clicks). 

Orient  the  base  of  the  detector  strictly 
according to the figure!

  

It  is  possible  to  install  using  the  Atra-5/621  bracket 
(supplied separately). 

5) 

Test Acoustic-channel and PIR-channel (see 

p. 9)

 

9  TEST 

If more than 60 minutes have passed since the 
detector  was  powered  on,  reinstall  the  battery 
and  close  the  detector

’s  cover,  or  light  up  the 

detector  indicator  with  any  button  of  the  laser 
tool. 

AC-channel:

 

1) 

Using  a  glass  break  simulator,  check  the 

detector  operation  for  glass  break  simulation, 

high-frequency  and  low-frequency  noise  (see 
table). 

Note

 

– It is recommended to use “Honeywell“: FG-

701  Glassbreak  Simulator, 

“DSCTM”:  AFT-100 

Glass-break Simulator. 

2) 

Check  in  the  event  log  of  the  receiver 

presence  of  the  “Alarm”  entry  on  the  2nd 
detection channel. 

PIR-channel: 
1) 

Perform 

TEST-pass

.

   

2) 

At  the  moment  of  detection, 

the  indicator  of  the  detector 
lights up for

 1 sec. 

3) 

Check in the event log of the 

receiver 

presence 

of 

the 

“Alarm”  entry  on  the  1st 
detection channel.

 

10 WARRANTY 

The  operation  warranty  period  is  5  years  from 
the date of operation start-up but no longer than 
years 6 months from the date of manufacturing 
subject to the requirements of the User guide. 