6  ADDING PROCEDURE 

 

1)

    When  using  the  detector  with  factory  set-

tings  (Security  Hub  compatible),  start  adding 
from  step 

3)

,  if  it  is  necessary  to  change  the 

operation  mode  of  the  detector,  remove  the 
detector cover (see p. 8). 

2)

  For  operating  with  Security  Hub  set 

Fre-

quency 1

 and 

mode 2

 using jumpers. 

3)

  Start  registration  on  the  Security  Hub  mobile 

app  or  web  app.  Registration  starts  for 

45-60 

sec

4)

 Activate the battery by pulling out the protec-

tive strip or re-install the battery. 
In  case  of 

unsuccessful  adding

,  remove  the 

battery  and  repeat  procedure.  Before  installing 
it  on  again,  wait  at  least  20  sec.  or  briefly  set 
the battery in reverse polarity.

 

5) 

Make  sure  that  the  adding  is  successful  on 

the Security Hub mobile or desktop app. 

 

7  INSTALLATION PLACE 

 

1) 

   Recommended  installation  height 

not  less 

than 2 m 

and at a distance of 

no more than 6 m

 

to the most distant point of the protected glass.

 

2) 

It is allowed to install the detector on the ceiling, 

wall, in window openings, between frames. 

 

3) 

It  is  not  allowed  to  operate  the  detector  in  a 

room with a high level of acoustic interference. 

4) 

Place the alarm loop wires away from pow-

erful power cables. 

 

 

To eliminate false alarms 

1) 

close  the  doors  and  vents  in  the  room  for 

the  period  of  protection,  turn  off  possible 
sources  of  strong  air  flows  (fans,  air  condition-
ers)  and  acoustic  interference  (broadcast  loud-
speakers, etc.); 

2)

 all areas of the protected glass must be with-

in  the  direct  line  of  sight  of  the  detector;  it  is 
prohibited  to mask the  detector  with

 

decorative

 

curtains, since in this case, the loss of its sensi-
tivity is possible. 

 

Not recommended installation places 

 

 

 

 

8  INSTALLATION PROCEDURE  

1) 

 

Remove cover

 

 

 

2) 

Remove PCB 

 

3) 

 Fix the base.

 

 

ATTENTION!

  Fix  the  detector  base  on  a  hard  surface 

to safely break out the plugs. 

 

 

4) 

 Install PCB.

 

5) 

 When  using  hardwired  detectors,  fix  the 

supplied  wires  in  the 

Zone,  GND

  terminals. 

Place a jumper on the 

Ext

 plug. 

6) 

Perform test of acoustic channel (see p. 

9

)

 

9  TEST 

 

1) 

Install jumper on

 GB 

plug.  

2) 

Turn on the detector. LED will turn on for no 

more than 20 sec. 

3) 

Close the cover. 

4) 

Using  a  glass  break  simulator,  check  the 

detector response for acoustic interference: 
-  for  high-frequency  -  2-fold  blinking  with  a 
pause of 0.1 sec, 
- for low-frequency - single switching on for 0.45 
sec. 

 

10  WARRANTY 

 
 

Operational  warranty  period:  5  years  from  the 
date of commissioning, but no more than 5 years 
6 months from the date of manufacture and sub-
ject to current user guide requirements. 

 

 