teko Astra-6131 User Manual Download Page 1

 

Astra-6131  

Wireless glass break detector 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

User guide 

 

 

 

 

Manufacturer: 
ZAO NTC TEKO 

Gafuri str. 71 
420108 Kazan, Russia 
+7(843) 528-03-69 

[email protected] 
www.teko.biz

 

 

 

Made in Russia 

 

         

   

Rev. 6131-v3_3_instr_en 

 

1  FUNCTION 

The  detector  is  designed to  detect  the  destruc-
tion of glass, generate an alarm notification and 
transmit a notification via a radio to the Security 
Hub controller. 
The  detector  supports  measurement  and 
transmission over the radio (in radio mode 2) of 
the residual capacity of the battery  with display 
in the event log when values of 30, 20, 10% are 
reached. 
The  frequency  of  transmission  of  values  is 
equal  to  12  sec.  (Rtst  jumper  installed)  or  60 
sec. (Rtst jumper not installed). 
The  detector  supports  connection  of  the  hard-
wired  detectors  with  normally  closed  contacts. 
The length of the wire is no more than 1.5 m.

 

 

2  DETECTION ZONES 

               Front view                    Side view 

 

 

Main detection zone

 

 

Probable detection zone 
(determined during testing see p. 9)

 

 

3  DELIVERY SET 

 

Delivery  set  includes:  dowels

 - 2 pcs., screws - 2 

pcs.,  jumpers 

–  5  pcs.  (installed),  battery 

(CR123

А, 3V installed) - 1 pcs., user guide – 1 

copy., label 

– 2 pcs. 

 

 
 
 
 

4  SPECIFICATIONS 

 

Acoustic channel operating frequencies:  
- first (high), kHz  .............................. from 4 to 6 
- second (low), Hz ..................... from 100 to 200 
Wireless coverage, m .................................. 100 
Supply voltage, V ........................ from 2,6 to 3,2 
Overall dimensions, mm .................

87 × 54 × 28 

Operating conditions 

Temperature range, 

°

С

............ from - 20 to + 50  

Relative air humidity, %

 ......... up to 98  at + 40 

°

С 

                                        

without moisture condensation

                                               

 

 

5  OPERATING MODES 

 

Setting  operating  mode  of  the  detector,  as 
well  as  LED  indication  of  notifications  are 
provided  within  10  minutes  after  battery 
insertion! 

 

Mode 

Plug 

Jumper 

Mode 2* (compatible 
with Security Hub) 
 
Mode 1  

Rmod 

   

 

 
  

  

 

Test signal 
transmission 
period**  

12 sec. 
 
60 sec.* 

Rtst 

   

 

 

   

 

Frequency 1* (compati-
ble with Security Hub) 
 
Frequency 3 

Lit 

   

 

 
   

 

Acoustic channel high 
sensitivity 
 
Acoustic channel nor-
mal sensitivity* 

GB 

   

 

 
 

   

 

Zone input on 
 
Zone input off* 

Ext 

   

 

   

 

* Factory setting. 
**Only for radio mode 2 