background image

 

Astra-6 (Volumetric Lens) 

 

Optic-Electronic PIR Motion Detector 

 

Operation Manual

 

 

 

 

 

 

 

 

 

 

 

The  present  operation  manual  is  intended  for  studying 
operation principle, running conditions and maintenance of PIR 
motion detector Astra-6 

(hereinafter “detector”) (Figure 1). 

The  manufacturer  reserves  the  right  to  make  alteration 
regarding refinement of the product without prior notification. All 
changes  will  be  imported  into  new  edition  of  the  operation 
manual. 

 

1  Function 

 

1.1 

Detector  is  intended  to  detect 

unauthorized 

access 

into 

closed 

protected area, and to generate an alarm 
notification    by  opening  of  alarm  relay 
contacts. 

1.2 

Power 

supply 

of 

detector 

is 

performed from any direct current source 
with  nominal  voltage  12V  and  pulsation 
amplitude not exceeding 0,1V. 

 

2  Principle of Operation 

 

Operation principle is based on 
registration  of  changes  in 
thermal emission flux occurring 
on  crossing  by  a  man  of 
detection  zone  consisting  of 
sensitive 

zones. 

Each 

sensitive  zone  consists  of  two 
elementary  sensitive  zones 
(figure 2).

 

Detector  sensitive  zones  are 
formed by Fresnel lens and bi-
areal 

pyroelectric 

radiation 

reciever.    
Pyroelectric  reciever  sends 
electric 

signal 

to 

microcontroller,  which  in  its 
turn  generates  an  “Alarm” 
notification  in  accordance  with 
pre-set  algorithm    by  opening 
optoelectronic relay circuit.  
 

Figure 2 

3  Specifications  

 

Technical Parameters of Optical Channel 

Detection range, m, not exceeding ............................................... 12

 

Detection area volume 
with viewing angle in horizontal plane ............................ 

12×12

 

Range of detected 
moving speed, m/s ....................................... from 0,3 up to 3,0

 

Resistance to ambient light, lx, not less than ...................  6500 

 

Recommended height of installation, m ........ from 2,4 up to 2,5

 

 

General Technical Parameters

 

Power supply voltage, V ................................... from 8 up to 15

 

Current consumption in stand-by mode and 
in “Alarm” mode, mA, not exceeding .................................... 15

 

Relay contacts permissible current, A, not exceeding ....... 0,08

 

Permissible voltage on relay 
contacts, V, not exceeding ................................................. 100 
Resistance of circuit connected to signaling zone, 
in stand-by mode, Ohm ...................................... from 6 up to 8

 

Overall dimension, mm, not exceeding..................... 7

5×58×48

 

Weight, kg, not exceeding ............................................... 0,051

 

 
 

Operating Conditions 

Temperature range, °C ................................ from -30 up to +50 

 

Relative air humidity,%  ................................... up to 95  at + 35 

°

С

 

without moisture condensation 

 
 

4  Delivery Set 

 

PIR motion detector Astra-6

 .................................................. 

1 pcs

 

Screw 2-3x30 ................................................................... 2 pcs 

 

Dowel 5x25 ...................................................................... 2 pcs 

 

Sealing material................................................................ 1 pcs 

 

User Instruction .............................................................. 1 copy

 

 

5  Structure 

 

 

 

Figure 3 

 

Detector  is  designed  as  a  unit  consisting  of  a  base  and 
removable cover. Printed circuit-board with radioelements and 
screw  terminal  block  for  outside  connections  is  mounted 
inside the unit (figure 3).  
Detector operability indicator for operation capability control is 
installed on the printed board. 
From  the  inner  side  of  the  detector’s  cover  there  is  a  fixing 
element installed, clamping and fixing the lens.  
Pyroelectric  detector  is  equipped  with  a  cap  with  reflector 
which forms short-range detection zone. 

 

ATTENTION! It is forbidden to operate detector without a 
cap.

 

 

Figure 1 

Summary of Contents for Astra-6

Page 1: ...cal Channel Detection range m not exceeding 12 Detection area volume with viewing angle in horizontal plane 12 12 Range of detected moving speed m s from 0 3 up to 3 0 Resistance to ambient light lx not less than 6500 Recommended height of installation m from 2 4 up to 2 5 General Technical Parameters Power supply voltage V from 8 up to 15 Current consumption in stand by mode and in Alarm mode mA ...

Page 2: ...is activated in 1 minute after installation of Mem plug or in 1 min after starting of detector stand by mode with jumper installed previously on Mem plug Alarm notification is indicated in 1 min after violation of protected area To switch the mode off and reset indication remove jumper from Mem plug or switch power off TEST pass allows revealing precise location of sensitive zones formed by the le...

Page 3: ...al terminal RES is provided Step 9 Using sealing material of distribution kit seal hermetically wire insertion hole and other holes to protect detector from air and insects ingress Step 10 Install jumper on Ind plug and Sens plag Remove jumper from Mem plug Step 11 Power detector up indicator flashes 1 time per 1 s during 60s starting of detector working mode Step 12 During starting of detector wo...

Page 4: ...y equipment 11 Recycling Detector is not dangerous for life and health of people and is safe for environment after termination of service life it should be recycled without special environment protective measures 12 Warranty 12 1 Quality Management System meets provisions of ISO 9001 2011 12 2 The manufacturer provides requirements compliance of detector in condition of observance of technical req...

Reviews: