Astra-551  

Combined Volumetric

  

Detector

 

 

 

 

User Instruction

 

Sales: 
Controlex GmbH 
 

Philosophenweg 31-33 
47051 Duisburg,Germany 
+49 (0) 203/393 91 188 

[email protected]

 

www.controlex.eu

  

Warranty service and 
technical support: 
TEKO-TD 

Prospekt Pobedy str. 19 
420138 Kazan, Russia 
+7(843) 261-55-75 

[email protected]

  

www.teko.biz

  

 

Made in Russia 

     

                   

Rev. 551-v1_1_instr_EN 

                          

1  FUNCTION 

The  detector  is  intended  for  detection  of 
unauthorized access into an enclosed area, and 
generation  of  an  alarm  notification    by  opening 
contacts  of  dedicated  signaling  relay  if  signals 
are present in both detection channels - infrared 
and microwave (IR and MW).

 

 

 

 

2  DETECTION ZONE 

 

 

3  SPECIFICATIONS 

 

Range of detected 
moving speed, m/s

 

 ..................... from 0.3 to 3.0 

Power supply voltage, V .................. from 8 to 15  
Current consumption, mA, max ......................16  
Overall dimensions, mm ............. 106.

5×72×51.5

 

Operating Conditions 

Temperature range, 

°

С ............from - 30 to + 50  

Relative air humidity, % .......... up to 95  at + 35 

°

С 

                                       

Without moisture condensation  

4  DELIVERY SET 

Delivery  set  contains  holders  and  fasteners 
(bracket 

–  1  pcs.,  dowel  –  2  pcs.,  screw  –  2 

pcs.), sealing material 

– 1 pcs. 

 

5  OPERATING MODE 

 

Operating mode 

Plug 

name 

Jumper 

position 

Frequency shift 
ON 

 

Frequency shift 
OFF

 

Freq 

 

 

 

“Alarm memory” 
ON

 

 

“Alarm memory” 
OFF

 

Mem 

 

 

 

High detectability

   

 

Normal detecta-
bility

 

Mode 

 

 

 

Indication ON 

 

Indication OFF 

Ind 

 

 

 

MW-channel 
test 

Mem 

See par. 9 

PIR

-

channel

 

test

 

Ind 

See par. 9 

 

6  INSTALLATION LOCATION 

 

1) 

   Recommended installation height is 2.2-2.5 m.

 

2) 

Install  detector  on  bearing  walls  and  carri-

ers. 

 

3) 

Alarm  loop  and  power  supply  wires  should 

be located far from power cables.

 

 
 