7 INSTALLATION PROCEDURE
1)
Remove cover
2)
Remove PCB
3a)
Installation on the
wall
3b)
Installation using
bracket
Detector base should be positioned strictly
as per figure!
4)
Replace PCB and
perform wiring
(see par.
8
)
5)
Perform TEST-pass
(see par.
9
)
8 WIRING
Perform wiring to detector`s terminals in
accordance with control panel operating
manual.
RELAY
–
terminals for detector connection to
alarm loop;
TMP
–
detector tampering control terminals;
GND, +12V
–
power supply terminals.
9 TEST-PASS
1)
Remove jumpers from
PIR
and
Mem
plugs.
2)
Power detector ON. LED starts flash during
60
sec.
3)
Close detector
.
4)
To detect sensitive zones carry out
TEST-
pass
in the secured zone with the speed of
0,3
and
3 m/s
.
On detection (indicator is lighted for
2s
) one
should stop, mark this position, then make step
back and continue moving
.
Repeat
TEST-pass
inversely
.
10 WARRANTY
The operation warranty period is 5 years from the date
of operation start-up but no longer than 5 years 6
months from the date of manufacturing
subject to the
requirements of Operating Manual.
*
For more detailed information refer to detector
Operating
Manual