teko Astra-531 PIR User Instruction Download Page 1

 

Astra-531 Ver.PIR

  

(Surface Lens) 

Optic-Electronic PIR Motion  

Detector

 

 

 

User Instruction

 

Sales: 
Controlex GmbH 
 

Philosophenweg 31-33 
47051 Duisburg,Germany 
+49 (0) 203/393 91 188 

[email protected]

 

www.controlex.eu

  

Warranty service and 
technical support: 
TEKO-TD 

Prospekt Pobedy str. 19 
420138 Kazan, Russia 
+7(843) 261-55-75 

[email protected]

  

www.teko.biz

  

 

Made in Russia 

 

     

 

        

Rev. 531-ikv1_0_instr_EN                         

 

 

1  FUNCTION 

Detector  is  intended  to  detect  unauthorized 
access  into  closed  protected  area,  and  to 
generate  an  alarm  notification    by  opening  of 
signaling relay contacts

 

 

2  DETECTION ZONE 

 

 

 

3  SPECIFICATIONS 

 

Range of detected 
moving speed, m/s

 ................. from 0,3 up to 3,0 

Power supply voltage, V ............. from 8 up to 15  
Current consumption, mA, max ......................18  
Overall dimensions, mm ..................... 

62×37×29 

Operating Conditions 

Temperature range, 

°

С .............. от - 20 до + 50  

Relative air humidity, % ........... up to 95 at + 35 

°

С 

                                      

Without moisture condensation  

4  DELIVERY SET 

Delivery  set  contains  holders  and  fasteners 
(bracket  -  1pcs.,  dowel 

–  2  pcs.,  screw  –  2 

pcs.), jumper 

– 2 pcs. 

 
 

 

 

5  OPERATING MODE 

 

Operating mode 

Plug 

name 

Jumper 

position 

High detectability

   

of PIR-channel 
 

 

Normal 
detectability

 

of PIR-channel 

PIR 

 

 

 

“Alarm  memory” 
ON

  

 

“Alarm memory” 
OFF

 

Mem 

 

 

 

TEST-pass

 

See par. 9 

6  INSTALLATION LOCATION 

 

1) 

   Recommended installation height is 5 m max.

 

2) 

Installation

 

on  ceiling,  on  a  wall,  in  window 

openings  and  between  window  frames  is 

al-

lowed

 

3) 

Alarm  loop  and  power  supply  wires  should 

be located far from power cables.

 

 

To eliminate false alarm hazards

 

It is recommended to close all doors, air-vents, 
switch  off  fans,  air-conditioners  and  other 
sources  of  intense  air flows  in the  room  during 
protection period.

 

 

Not recommended installation locations 

 

 