ADDING PROCEDURE
1)
Remove detector cover.
2)
For operating with Security Hub set
Frequency 1
and
Mode 2
using jumpers.
3)
Start registration on the Security Hub mobile app or
web app. Registration starts for
45-60 sec
.
4)
Insert battery into the detector.
Make sure that the registration is successful on the
Security Hub mobile app. If registration is unsuccessful,
repeat the procedure.
7
INSTALLATION PLACE
1)
It is allowed to install the detector on a wall,
ceiling, in a door/ window opening, in the corner of the
room.
2)
Mount the detector on a load-bearing wall or other
load-bearing structural elements.
To eliminate false alarms
It
is
recommended
to
close
all
doors,
air-vents, switch off fans, air-conditioners and other
sources of intense air flows in premises during protec-
tion period.
Not recommended installation places
8 INSTALLATION PROCEDURE
1)
Remove the cover
2)
Remove the PCB
3a)
Mounting on a wall or
ceiling
3b)
Mounting in a corner
Attention!
For safe extrusion of the caps fix the
detector base on a hard flat surface.
3c)
Mounting with a
bracket
4)
Install the PCB
5)
Install the battery
6)
Perform TEST-pass (see p. 9).
9 TEST PASS
1)
Install jumper on the
PIR
plug
.
2)
Power up the detector (install the battery). LED
flashes once every 2 seconds for a period of not more
than 60 sec.
3)
Close the detector cover.
4)
After the detector enters the operating mode,
perform a
test pass
across the protected area
at a
speed of 0.3 m/s to determine the sensitivity zone.
At the moment of detection (LED lights up for 1 sec),
stop, mark this position, go back two steps, then con-
tinue moving forward. Repeat the test pass in opposite
direction.
10 WARRANTY
The operation warranty period is 5 years from the date
of operation start-up but no longer than 5 years 6
months from the date of manufacturing subject to the
requirements of Operating Manual.