Astra-5131 ver. C
(Curtain-type Lens)
Wireless Optic-Electronic
PIR Motion Detector
User Guide
Manufacturer:
ZAO NTC TEKO
Gafuri str. 71
420108 Kazan, Russia
+7(843) 528-03-69
Made in Russia
Rev. 5131sh-v2_2_instr_en
1 FUNCTION
The detector is intended for detection of an intrusion
into a secure space of an enclosed area, forming an
alarm notification and transmitting alarm signal to the
Security Hub via radio.
The detector provides measurement and transmission
via radio:
a) the residual capacity of the battery in operating
Mode 2
(see below) when the capacity value is 30,
20 and 10%.
b) ambient temperature (processed by Centrtal
Control Panel or Security Hub)
The transmission interval is 12 s (with
Rtst
plug
jumpered) or 60 s (with
Rtst
plug opened).
2
DETECTION ZONE
3 SPECIFICATIONS
Range of detectable
moving speed, m/sec
.............................. from 0.3 to 3.0
Wireless coverage range, m .................................... 100
Operating frequency range, MHz ............................ 433
Power supply voltage, V ......................... from 2.4 to 3.0
Dimensions, mm ........................................ 85
× 50 × 30
Operating Conditions
Temperature range,
°
С ........................ from - 20 to + 50
Relative air humidity, %....................... up to 98 at + 40
°
С
Without moisture condensation
4 DELIVERY SET
Detector delivery set includes: bracket - 1 pc., dowel
–
2 pcs., screw
– 2 pcs., jumper – 4 pcs. (installed),
battery (CR 123A, 3V) - 1 pc., user guide
– 1 copy.
5 OPERATING MODES
Mode
Plug
Jumper
Mode 2
* (compatible with
Security Hub)
Mode 1
Rmod
Test signal
transmission
period**
12 sec.
Rtst
60 sec.
Frequency 1
(433,42 MHz)
(compatible with Security
Hub)
Frequency 3
(434,42 MHz)
Lit
High detectability
Normal detectability
PIR
* Factory setting.
** For Mode 2 only
Setting operating mode of the detector, as well as
LED indication of notifications are provided within
10 minutes after battery insertion!