teko Astra-5 Ver.A User Manual Download Page 2

Changing the 

indication mode

 of 

“Alarm” is 

made by closing the 

Ind

 contact for 

at least 10 

sec. 

 

 

-

 

1-time flash

 

– indication 

enabled

-

 2-time flash

 

– indication 

disabled.

 

 

6  INSTALLATION PLACE 

 

1) 

   Recommended installation height is 2.3+-0.05 

m.

 

2) 

Install  detector  on  bearing  walls  and  carri-

ers.  

 

3) 

Alarm  loop  and  power  supply  wires  should 

be located far from power cables.

 

 

To eliminate false alarm hazards

 

1) 

It  is  recommended  to  close  all  doors,  air-

vents, switch off fans, air-conditioners and other 
sources  of  intense  air flows  in the  room  during 
protection period

.

 

2) 

Any  furniture  or  interior  items  within 3 m  of 

the  detector  which  could  make  possible  for  an 
animal  to  climb  above  the  floor  level  must  be 
removed

.

 

 

Not recommended installation locations 

 

 

 

7  INSTALLATION PROCEDURE  

 

1) 

Open the 

detector by pushing 
the cover latch out 
of the groove in the 
base  

 

 

2) 

 Fix the bracket 

to location chosen 
for installation 
of the detector

 

 

3) 

 Install the detector 

on the bracket and 
connect the wires (see 
section 8). 

Orient  the  detector 
base 

strictly 

vertically  according 
to the drawing!

 

 

There  is  a  possibility  of  installation  using  a  ball 
bracket (supplied separately).

 

4) 

 Replace the detector 

cover 
(until it clicks). 

 

5) 

 Perform 

Test

 (see. 

section 

9

). 

 

 

6) 

Set the required indication 

mode (see section 

5

). 

 

 

 

 

8  WIRING 

 

Perform  wiring  to  detector`s  terminals  in 
accordance  with  control  panel  operating 
manual. 

 

TMP 

– 

detector tampering control terminals;

 

Relay 

  terminals  for  detector  connection  to 

alarm loop; 

+12V, GND 

 power supply terminals. 

 

9  TEST 

1) 

Switch  on  the  detector 

power 

supply. 

The 

indicator  will  flash  for  a 
maximum of 

60 seconds. 

2) 

To  detect  sensitive 

zones  carry  out 

TEST-

pass

    across  protected 

area  with  the  speed  of 

0,3 

and 3 m/sec . 

Stop  upon  detection  (indicator  lights  up  for 

2sec

),  mark  position,  then  make  a  step  back 

and continue moving. 

 

Repeat 

TEST 

inversely

The  sensitivity  zones  formed  by  the  lens  will  be 
located  in  the  middle  between  the  marked 
positions. 

 

10  WARRANTY 

 

The  operation  warranty  period  is  5  years  from 
the date of operation start-up but no longer than 
5 years 6 months from the date of manufactur-
ing

 subject to the requirements of User guide. 

 

 

 

 