teko Astra-3221 User Manual Download Page 2

5  OPERATION MODES   

Attention! 

Setting operation mode of the detec-

tor, as well as LED indication of notifications are 
possible  within  no  more  than  10  minutes  after 
battery insertion! 

 

5.1 

 

RF supervision/  No RF supervision

 

Panic button supports two operation modes: 

With  RF  supervision

  (when  using  the  panic 

button as a stationary device),  

Without  RF  supervision

  (when  using  the 

panic button as a mobile (wearable) device). 

 

Sequencing: 
1)

 Remove the base of the detector (see 

p.6

2)

 Activate battery by pulling out the insulator 

3) 

By the LED indication check the mode: 

- 1-time flash

 

– with RF supervision

,  

- 2-time flash

 

– without RF supervision

 

4)

 To change the mode, wait for 10 sec., press 

the 

panic button

 and hold it for at least 10 sec. 

until the LED flashes, 1-time or 2-time, depend-
ing on the set mode. 

 
5.2 Radio mode selection 

 

The radio mode of the detector is configured by 
closing the metallized contacts on the PCB. 

 

Sequencing: 
1)

 If after activating the 

battery more than 10 
minutes have passed: 
reset the battery, wait at 
least 

10 sec.

  

2)

  Close  the  metallized 

Rmod

  contact  until  the 

indication  appears  (at 
least 10 sec). 
 

3)

  After  turning  on  the  LED,  determine  the  set 

radio mode: 

- 1-time flash

 

– mode 1,  

- 2-time flash

 

– mode 2 (compatible with Secu-

rity Hub). 

 

4)

 Close the metalized 

Lit

 contact until the LED 

indication appears (not less than 10 sec). 

5)

  After  turning  on  the  LED,  determine  the  set 

mode: 

- 1-time flash

 

– frequency mode 1 (compatible 

with Security Hub),  

- 3-time flash

 

– frequency mode 3. 

 

When  changing  modes  on  a  registered  de-
tector  it  is  necessary  to  re-register  the  de-
tector! 

 

6  ADDING PROCEDURE 

1) 

De-assemble the panic button. 

 

2) 

Select  mode  with  or  without  RF  supervision 

(

p.  5.1

)  if  it  is  necessary  (no  need  for  Security 

Hub)

3) 

Set radio mode and frequency mode (p

. 5.2

if it is necessary (no need for Security hub). 

4) 

Start  registration  on  the  Security  Hub  mobile 

app. Registration starts for 

45-60 sec

5) 

Activate or re-activate the battery. 

6) 

Check the adding in the Security Hub mobile 

App.

 

7) 

In  case  of  successful  adding  activate  the 

second battery and assemble the panic button. 

 

7  INSTALLATION  PROCEDURE  

 

 

 

As  a  stationary  device  with  RF  supervi-

sion:

 

- remove the base; 
- remove the PCB; 
- fix the base of the detector in the chosen 
place; 

- install the cover with the PCB fixed on it into 
the base. 

 

As  a  mobile  device  without  RF  supervi-

sion: 

attach  to  clothes  with  a  clip  or  use  a  cord 

(cord is supplied separately)

 

8  WARRANTY 

The operation warranty period is 1 year from the 
date of operation start, but no longer than 1 year 
6 months from the date of manufacturing

 subject 

to the requirements of User guide. 

 

 

 