![teko astra-10 Operation Manuals Download Page 2](http://html1.mh-extra.com/html/teko/astra-10/astra-10_operation-manuals_1077171002.webp)
10-3_v3_10_en
2
5.4.6 Wiring options:
-
when connecting to control panel Astra-812 or Astra-812M
–
see Figure 3;
-
when connecting to control panel Astra-712/x
– see Figure 4;
Figure 3
Figure 4
5.4.7
Seal hermetically the wire insertion hole to protect the alerter
from ingress of dust and insects
5.4.8
Re-install the cover:
–
align
cover’s ledges with base’s slots;
–
clasp the cover to the base;
–
turn the cover clockwise until it stops (until it clicks).
6 Maintenance
To provide failsafe operating of an alarm system, do the mainten-
ance works
at least one time per 6 months
.
Maintenance of the alerter includes the following works:
–
Inspection of alerter’s housing integrity;
–
Inspection of reliability of alerter’s fixation on installation sur-
face;
–
Inspection of reliability of wire connections;
–
Cleaning from contaminants;
–
Inspection of alerter’s operability by connecting it to a power
supply source. LEDs should light on with equal brightness, em-
bedded piezoelectric acoustic emitter should issue sound sig-
nals.
7 Labeling
On a label attached to the housing of the alerter are:
–
manufacturer’s trademark;
–
abbreviated name of the alerter;
–
firmware version;
–
month (the first three letters) and year (the last two digits) of manu-
facture;
–
conformity mark (if certificate is available);
–
bar-code duplicating the textual information.
8 EC Conformity Declarations
This product is in conformity with the provisions of:
EMC 89/336/EEC
EN 61000-6-3:2005 Electromagnetic compatibility (EMC) - Part 6-3: Ge-
neric standards - Emission standard for residential, commercial and light-
industrial environments
EN 50130-4/1995 + A1:1998 + A2:2003 + Corrig. 2003 Alarm systems -
Part 4: Electromagnetic compatibility - Product family standard: Immunity
requirements for components of fire, intruder and social alarm systems
EN 60950-1: 2001+A11:2004+Corrig.2004 Safety of information technol-
ogy equipment
9 Recycling
The alerter is not dangerous for life and health of people and is safe for
environment. On expiry of service life it should be recycled without spe-
cial environment protective measures.
10 Warranty
10.1 Quality Management System meets provisions of ISO 9001-2011.
10.2 The manufacturer guarantees compliance of the alerter with the
technical requirements provided the customer observes the standards of
operation, transportation, storage and installation of the device.
10.3 The storage warranty period is 2 years and 6 months from the date
of manufacture.
10.4 The operation warranty time is 2 years from the date of operation
startup but not longer than 2 years 6 months from the date of manufac-
ture.
10.5 The manufacturer commits to replace or repair the product during
the warranty period.
10.6
The warranty does not come into effect in following cases
:
-in case of non-observance of this operation manual;
-mechanical damage of the product;
-repair of the alerter by any other party except the manufacturer.
10.7 This warranty applies to the alerter only, not to equipment of third
part manufacturers used jointly with the detector.
User should keep in mind that correctly installed signalling system serves
to decrease the risk of such events as larceny, robbery or fire, but not to
avoid them at all.
The manufacturer bear no responsibility for death, injury, damage of
property or any other kinds of accidental or premeditated damages,
based on user’s statement that the device failed to implement its
function.
Sales:
Controlex GmbH
Warranty service and
technical support:
ТЕКО-TD
Philosophenweg 31-33
47051 Duisburg, Germany
Phone: +49 (0) 203 / 393 91 188
Fax: +49 (0) 203 / 393 91 189
GSM: +49 (0) 178 / 218 48 22
E-mail:
Web:
www.controlex.eu
Prospekt Pobedy str. 19
420138 Kazan, Russia
Phone: +7 (843) 261-55-75
Fax: +7 (843) 261-58-08
E-mail:
Web:
www.teko.biz
Made in Russia