![Teknion B AEHP Installation Manual Download Page 3](http://html.mh-extra.com/html/teknion/b-aehp/b-aehp_installation-manual_1076835003.webp)
WARNING
No drywall fixations allowed.
•
The purchaser and installer are responsible to ensure appropriate methods for a secure and safe
•
installation that meets all the applicable local building codes and laws.
Studs must be attached to ceiling and floor structures as per building code requirements and
•
must be load bearing studs.
Wood studs should be minimum 2” x 4”.
•
Steel studs should be minimum 20ga x 3-
⅝
”.
•
Studs must be 12’ high or less, for installation on higher studs, please refer to the engineer of
•
record.
If the wall on which the product is installed supports vertical weight or lateral winds, refer to
•
the engineer of record.
If installed in seismic region, refer to the engineer of record.
•
Overdriving may result in torsional failure of the fastener or tearing of the wall.
•
ATTENTION
Aucune fixation aux cloisons sèches autorisée.
•
L'acheteur et l'installateur sont responsables de s'assurer des méthodes appropriées pour un
•
installation conforme aux lois et codes du bâtiment applicables.
Les montants doivent être fixés aux structures de plafond et de plancher conformément aux
•
exigences du code du bâtiment et doivent être des montants porteurs.
Les montants de bois doivent mesurer au moins 2 ”x 4”.
•
Les montants en acier doivent mesurer au moins 20ga x 3-
⅝
”.
•
Les montants doivent avoir une hauteur de 12 pi ou moins, pour une installation sur des
•
montants plus élevés, veuillez vous référer à l'ingénieur en charge.
Si le mur sur lequel le produit est installé supporte un poids vertical ou des vents latéraux,
•
reportez-vous à l'ingénieuren charge.
S'il est installé dans une région sismique, consultez l'ingénieur en charge.
•
Un usage non recommandé peut entraîner une rupture des fixations un arrachement du mur.
•
#3.6
Expansion Casegoods Installation Guide / Guide d'installation
2021-01-19 14:27
BM_R, BH_WB, BH_CB, BH_PT, BH_MT, BH_EP, BH_LB, BH_L, BH_LT, BH_RB, BH_PP & BHK__
-
Height-Adjustable Table & Kneespace - Mid-Height / Table ajustable en hauteur & Module - Mi-Hauteur
3 / 9
L04-64040_R01
2046
For additional information on this installation contact Technical Support. Pour plus d'informations sur cette installation contactez le support technique.
Dryw all 1/2" + Wood stud 2" x 4"
Cloison s
èche ½ " + Montant Bois 2" x 4"
5/16" Lag Screw x 2.5" w ith 5/32" pilot hole
5/16" Vis Tire-Fond x 2.5" avec pr
é-trou 5/32"
Dryw all 1" + Wood stud 2" x 4"
Cloison s
èche 1" + Montant Bois 2" x 4"
5/16" Lag Screw x 3" w ith 5/32" pilot hole
5/16" Vis Tire-Fond x 3" avec pr
é-trou 5/32"
#12 Self-drilling screw x 2"
#12 Vis autoper
çante x 2"
Wall fixation minimum requirements
Exigences minimales de fixation murale
Dryw all
½ " + Metal Stud
Cloison s
èche ½ " + Montant Métal
Dryw all 1" + Metal Stud
Cloison s
èche 1" + Montant Métal
#12 Self-drilling screw x 1.5"
#12 Vis autoper
çante x 1.5"